Chapter 5: Local Management5-222M46-04R/2M46-04RDC User’s Guide3. Press ENTER. If the TFTP gateway IP address entered is a validformat, the cursor returns to the beginning of the TFTP Gateway IPAddress field. If the entry is not valid, the Event Message Linedisplays “INVALID TFTP GATEWAY IP ADDRESS OR FORMATENTERED”. Local Management does not alter the current value, butit does refresh the TFTP Gateway IP Address field with the previousvalue.4. Use the arrow keys to highlight the SAVE command.5. Press ENTER. The Event Message Line at the top of the screendisplays “SAVED OK”.5.7.5 Setting the Device DateThe 2M46-04R is year 2000 compliant so that the Device Date field canbe set beyond the year 1999. To set the system date, perform the followingsteps:1. Use the arrow keys to highlight the Device Date field.2. Enter the date in this format: MM/DD/YYYY3. Press ENTER to set the Device Date to the date in the input field.4. Use the arrow keys to highlight the SAVE command at the bottom ofthe screen and press ENTER.If the date entered is a valid format, the Event Message Line at the top ofthe screen displays “SAVED OK”. If the entry is not valid, LocalManagement does not alter the current value, but it does refresh theDevice Date field with the previous value.NOTEIt is not necessary to add separators between month, day, andyear numbers, as long as each entry uses two numericcharacters. For example, to set the date to 08/29/1997, type“08291997” in the Device Date field.