Chapter 1212-7A shift of the ADF upward by 1 mm will increase theregistration along the left bottom of the paper by about0.5 mm.3) Place A4 (LTR) paper in the cassette or the manualfeed tray.4) Open the ADF, and place an A5 (STMTR) originalon the copyboard glass.5) Close the ADF, and make a copy in Direct.6) Check the copy image, and check to make sure thatthe area outside the image is free of fogging.7) If fogging is found, the position of the white sheetmay be wrong; check its positioning. If no fault isfound, try skew removal once again.12.5.2.2 Left/RightRegistration Adjustment 0006-3205Using the ADF, make a copy of the sheet in Direct,and check to make sure the left/right registration is 10+/- 1 mm.F-12-101) Pick the tab [1], and detach the white plate [2].F-12-112) Loosen the screw [3], and move the slide guide tothe front/rear with reference to the index graduatedat 1-mm intervals until the registration is asindicated.F-12-12MEMO:A shift of the slide guide up by 1 mm will increase theregistration on the right (top of paper) by 1 mm.Do not remove the screw [3]; otherwise, you mustwork as instructed for mounting of the slide guide.12.5.3 Adjusting the EllectricalSystem12.5.3.1 Registration ArchAuto Adjustment 0006-3207Adjust the registration arch for the ADF registrationroller as follows:1) Press the Additional Functions key and the # key tostart service mode.2) Press the Left/Right Arrow key so that 'TESTCopy of the test sheet(feeding direction)10±1mm[1][2][3]