imageFORMULA DR-G1130/DR-G1100 Series Service GuideimageFORMULA DR-G1130/DR-G1100 Series Service Guide April 2013Rev. 1 Page 10F. Special ToolsIn addition to the standard tools used to service these devices, the followingspecial tools should also be carried in each group of five (5) service technicianswhen servicing an imageFORMULA DR-G1130/DR-G1100 Series machine.Special Tools List (Table 8)Description Part Number1 RemarksScale adjustment sheet TKM-0348 For the scale adjustment (10 sheets/set)Density adjustment sheet TKM-0347 For the density adjustment (10 sheets/set)Test sheet TKM-0271 For the general image check (10 sheets/set)1 Item Numbers and Part Numbers are subject to change due to engineering changes, etc.G. Consumable PartsConsumable parts are defined as those parts having a limited yield that will bereached during a customer’s specific machine operation and should be replacedas needed. Examples of consumable parts may include but are not limited to feedrollers, separation rollers, etc. The consumable parts provided below show anestimated yield to assist in the initial parts/supplies planning.Note: All consumable parts shown in the below table are for reference purposesonly and are subject to change without notice.Consumable Parts (Table 9)Description Item Number1 Expected Life3(sheets)Pickup roller MG1-4806-000 Approximately450,000sheetsFeed roller MA3-0002-000Retard roller MG1-4814-000Separation cover MF1-4799-000Approximately6,000,000sheets1 Item Numbers and Part Numbers are subject to change due to engineering changes, etc.3 Estimated average values in the field, based on the number of sheets separated, not the size of the sheets scanned. Data is subjectto change depending upon many factors including, without limitation, environment, and customer handling of the scannerequipment.