16English42N_S 42N_E 17English42N_S 42N_EGeneral information42N - FAN COIL UNITSAfter installation thoroughly test system operation and explain all•system functions to the owner.All of the manufacturing and packaging materials used for your•new appliance are compatible with the environment and can berecycled.Dispose of the packaging material in accordance with local•requiremements.When installing the electric heater kit and after connecting the•electric cables, cover the connectors using the silicon rubber caps.Check that the coil is fixed to the structure to ensure its correctground connection.Unit operationIn order to avoid electric shock, fire or injury, stop the unit and•disconnect the safety switch in case of abnormal events (such as smellof burning) and call Carrier Service for further instructions.Do not place containers filled with liquids or other objects onto the unit.•MaintenanceWArNING: Disconnect the mains power supply prior to any maintenanceoperations or prior to handling any internal parts of the unit.A routine maintenance should be carried out on the unit to check the•correct operation of the electric connections and protection devices.Maintenance operations must be carried out by specially trained•personnel.Do not attempt to repair, move, modify or re-install the unit on your•own. To avoid electric shock or fire make sure these operations arecarried out by qualified personnel only.Contact the qualified service if one of the following events takes place:•- hot or damaged power supply cable;- unusual noise during operation;- frequent operation of the protection devices;- unusual smell (such as smell of burning).Choosing the installation siteChoose an area free from obstructions which may cause irregular air•distribution and/or return.Check that the wall surface is flat enough to allow easy and safe•installation of the unit. The wall structure should be strong enoughto carry the unit weight and avoid deformation, rupture or vibrationduring operation.Consider using an area where installation is easy.•Choose a position that allows for the clearances required (see•drawing).Look for a position in the room which assures the best possible air•distribution.Install unit in a position where condensate can easily be piped to an•appropriate drain.Positions to avoid:Exposed to direct sun.•Too close to heat sources.•On humid walls or positions with water hazard, e.g. laundry premises.•Exposure to oil vapours (e.g. kitchens, workshops).•Where curtains or furniture may obstruct free air circulation.•… any obstruction of the unit air outlet or return. Leave 1 metreminimum of free space (See fig. 1)… exposure to oil vapours (See fig. 2)… installation in areas with high frequency waves (See fig. 3)… any rise in the condensate drain piping.… horizontal condensate drain piping with less than 2% slope(See fig. 4)... slack on electrical connections (See fig. 5)... disconnecting water connections after installation (See fig. 6)… exposure to direct sunshine, when unit is operating in cooling mode;always use shutters or shades (See fig. 7)… positions too close to heating sources which may damage the unit(See fig. 8)… connecting condensate piping to sewage system drain withoutappropriate trap (See fig. 9)… only partial insulation of the piping (See fig. 10)… installation not correctly levelled which will cause condensatedripping (See fig. 11)… flattening or kinking pipes or condensate pipes (See fig. 12)Warnings: avoid...Fig.13.Dimensions (mm) and weight, cabinet unitX . Cabinet version . Slots for wall vertical fixing . Condensate discharge Ø 20 mm O.D. drainconnection . Cover panels (accessories) . Supporting feet (accessories) . Slots for horizontal ceiling fixingDimensions (mm) and weight, concealed unitY . Concealed version . Condensate discharge Ø 20 mm O.D. drainconnection . Supporting feet (accessories) . Cool Ø 3/4” gas female . Heat Ø 1/2” gas female* Only for unit E19.Fig.16.1 . Minimum distance from the wallFig.17.Supporting feet and cover panels assembly forfloor-mounted vertical unitFig.18.Example of installation of unit with cabinet2 . Turn by 180°Fig.18A.Example of vertical installation of concealed unitFig.18B.Distance between panel – concealed unitA . Intake grille sizeB . Supply grille sizeC . Panel sizeFig.19.3 . Screw anchor with double screw4 . Air ventFig.21.Space for water connectionsFront view . IN . OUT . Cool Ø 3/4” gas female . Heat Ø 1/2” gas female . Condensate drain . FloorFig.22.Space for water connectionsTop viewL e g e n d Fig.23-24-25.5 . Control box panel6 . Hooks for control fixing7 . Temperature sensor8 . No. 2 screws for coil earthing9 . Front drain pan10 . Rubber tabs for coil hook11 . Thermoelectric valve head12 . Cold water circuit13 . Hot water circuitFig.27.Control box panel for versions without electricheater . Control connection cables . Motor connection cables . Power supply cables (230V ~) . Cables . Fan motor capacitor . Cable holder . Power supply unit terminal block . Supplementary motor speed wires . Utility terminal blockFig.28.Control box panel for version with Low Powerelectric heaterh . Electric heater cablesi . Fuse Holder . Control connection cables . Motor connection cables . Power supply cables (230V ~) . Cables . Fan motor capacitor . Cable holder . Power supply unit terminal block . Supplementary motor speed wires. Utility terminal blockFig.28b.Control box panel for version with High Powerelectric heaterh . Electric heater cables . Control connection cables . Motor connection cables . Power supply cables (230V ~) . Cables . Fan motor capacitor . Cable holder . Power supply unit terminal blockq . Power supply electric heater terminal block . Supplementary motor speed wiress . Relay for high power electric heater. Utility terminal blockFig.29.Motor fan wire connectionsa blue (motor neutral)b red (ultra low speed)c white (medium speed)d black (super high speed)e yellow (low speed – not connected)f orange (high speed – not connected)Fig.30.Control type “A”Fig.31.Control type “B”Fig.29-30-31.14 . ON/OFF/fan speed selector15 . Blue LED - cooling operation16 . Seasonal changeover button17 . Red LED - heating operation18 . Yellow LED - automatic operation (only for type “B”)19 . Energy saving button20. Yellow LED - energy saving operation21 . Temperature knobFig.32.22 . Control23 . Screw to close the control24 . Control cable25 . Control box panel26 . Metal plate to fix the control27 . ScrewsFig.33.28 . Screw29 . Screw anchorFig.34.30 . Minimum temperature sensor (optional)31 . Air sensor32 . Jumper to select remote temperature sensor orinternal sensor33 . Internal temperature sensor34 . Dip-switch selectorsFig.35.X . Control internal sensorY . Unit - mounted sensorFig.36.35 . Protection grille36 . Safety thermostatFig.37.Concealed units size of return/supply duct.Fig.39-40.43 . Filter tabsFig.41.Tangential unit with “Low Energy Consumption Fan Motor”Fig.42.Centrifugal unit single shaft with “Low EnergyConsumption Fan Motor”Fig.43.Centrifugal unit dual shaft with “Low EnergyConsumption Fan Motor”General informationUnit installationread this instruction manual thoroughly before using the unit andkeep it for further consultation even after installation.The unit complies with all applicable standards for EC marking•(for further details see Declaration of Conformity).The installation must be carried out by a qualified installer.•For safety reasons, installers are required to read the general•information carefully.Follow all the instructions below to ensure safety.•Inspect the unit for damage due to improper transport. Do not install•or use damaged equipment.To prevent fire, explosion or injury, do not operate the unit near•dangerous substances or close to naked light equipment.Ensure that national safety code requirements have been followed•for the main supply circuit. Follow all current national safety coderequirements. Ensure that a properly sized and connected groundwire is in place.Check that voltage and frequency of the mains power supply are•those required for the unit to be installed; the available power must beadequate to operate any other appliances connected to the same line.Make sure that properly sized disconnecting and safety switches are•installed.The manufacturer declines any liability fror damage resulting from•modifications or errors in the electrical or hydraulic connections.Failure to observe the installation instructions, or use of the unit underconditions other than those indicated in the table “Operating limits” ofthe unit installation manual, will immediately invalidate the unit warranty.Installationreceipt of unitCheck that packaging is undamaged.•Unpack unit and check immediately for damage during transportation.•Packaging contains the base unit and, if supplied, the unit cabinet.•Verify that all components ordered are supplied.•Unit preparationTake out and position template printed on the packaging. It is•advisable to keep cabinet packed until installation is complete.To install the cabinet, position it onto the base unit and fix it to the•special tabs on the unit rear side and then secure it with the twoscrews supplied (See fig.14-15).If the unit is installed at 150 mm from the floor or lower, use the angles•supplied with the base unit to prevent the user from touching themoving parts (See fig.14-15).If, instead, the unit is installed higher than 150 mm from the floor, use•the rear closing grille kit (code 42N0954-42N0955-42N0956-42N0957)according to the unit size. For horizontal installation at more than 2.5meters from the floor, the angles supplied need not be used.For horizontal installation at more than 2.5 meters from the floor, the•angles supplied need not be used.InstallationBefore proceeding to unit installation, it is recommended to assemble•the accessories according to the instructions supplied with the kit.It is advisable to lock the cover on the opposite side to the control or•on both sides if the control is not positioned on the unit.Knock out the prepunched part of the cover to insert the screw.•Furthermore it is possible to lock the control cover.•CAMBIATO: 16 Power supply unitterminal blockq . Heating element cable holder |
Related manuals for Carrier 42N *** E Series
Carrier 42N_S Installation And Operation Manual
Carrier 42N S Installation And Operation Manual
Carrier 42n Installation And Operation Manual
Carrier 40VM Series Installation And Operating Instructions Manual
Carrier XCT Series Installation And Owner's Manual
Carrier 38C Series Installation, Operation And Maintenance Manual
Carrier 42HQM Series Installation Manual
Carrier 42PHQ Series Installation Manual
Carrier XCT 7 Series Installation And Owner's Manual
Carrier 50TCM Series Installation, Operation And Maintenance Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine