– 95 –No. Part nameElectric partsbox assemblyProcedures1) Follow the procedure .2) Remove screw of earth lead attached to theend plate of the evaporator.3) Remove the lead wire cover, and removeconnector for the fan motor and connec-tor for the louver motor from the electricparts box assembly.4) Pull out TC sensor from sensor holder of theevaporator.Remarks1) Hook the top part of the electric parts boxassembly onto the claws on the back body,and secure it using the fixing screw.Now attach the display unit. Connect theconnectors for the fan motor and louver motor.2) Secure the grounding wire using the fixingscrew. Insert the TC sensor into the sensorholder.* Be absolutely sure to loop the groundingwire and TC sensor leads once at thebottom.5) Disengage the display unit by simply pushingat the top of the display unit.6) Remove the fixing screw that secures theelectric parts box assembly, and remove theElectric partbox coverassembly.connectorAC fan motorconnectorLouver motorFixing screwEarth ScrewTC sensorconnectoFan motorFILE NO. SVM-07013-1 (42NQV025H,42NQV035H,42NQV035M)