EN- 19 -- 18 -4. Use with the badge reader4.5 Triggering of a discreet emergencyalarmPress and hold the or button for 2 seconds.The LED changes from red to green to confirm the action.The telephone transmitter calls from the3rd number programmed. The 1st and 2nd numbers arenot called for the discreet emergency alarm.4.6 Triggering of an emergency alarmwith sirenPress and hold the or button for 2 secondsto trigger:- a call cycle from the transmitter to the programmednumbers (starting with the 1st number).- an audible signal from an associated siren.The LED changes from red to green to confirm the action.Press OFF to stop an active emergency alarm with siren,then swipe the badge.4.7 Clearing defectsEach time the system is activated or deactivated, the alarm controlunit will inform you that an event (or defect) is stored by using aseries of beeps or a refusal to switch on.These events (intruder detection, product defect, open entry, etc.)can be cleared so as not to be signalled by the control unit.The system must be off.If you do not have a touch screen keypad, you canclear defects by using the badge reader:Press the button for 5 seconds, then place the badge on thedetection zone.The LED changes from red to green to confirm the action.The alarm control unit emits a series of beeps, stops, then emitsone more beep.This function is used to trigger a call with yourtelephone transmitter to warn relatives that you are in a situationof distress. It also sets off the sirens with a specific tone.The or buttons must be configured in Mode C (see table§ 4.1).OK>2sSOSOUOK>2sSOSOU+>5sBeep, beep, beep .......BeepThis function is used to trigger a discreet alarm with yourtelephone transmitter, without any aggressor being aware of it(no audible signal).The or buttons must be configured in Mode B (see table§ 4.1).5. Use with your simple keypadThe keypad is used to activate or deactivate your systemfully or by zone via an access code.You also have a direct access SOS button to warn relativesthat you are in danger.5.1 Activating the system• Complete activationÊ Enter your access code (6 digits).Ë Press .The LED changes from red to greento confirm the action.• Operation by zone (1 to 8)Example: zone 4Ê Enter your access code (6 digits).Ë Press , then , then .The LED changes from red to green toconfirm the action.5.2 Deactivating the system• Complete shutdownÊ Enter your access code.Ë Press .The LED changes from red to green to confirm the action.• Shutdown by zoneExample: zone 4Ê Enter your access code.Ë Press the button, then , then .The LED changes from red to green toconfirm the action.Depending on the installation settings, the alarm controlunit will or will not emit beeps to confirm the activation ordeactivation actions.OKON12OKON1 2LEDActivateEmergencyalarmwith siren buttonShutdownInformationupstairsOKOFF12OFFOKOFF12Wrong code entered: The keypad is locked for 90seconds after five attempts to enter the wrong code.If there are many attempts to enter a wrong code (21attempts), an alarm cycle will be triggered.