EN- 21 -- 20 -5.3 Override operationÊ The alarm control unit denies the activation.It emits a series of beeps to warn the user.On the keypad, the LED flashes red.Ë Enter your access code a second time then pressON within 5 seconds after first pressing the button.The LED changes from red to green to confirm the action.The alarm control unit emits a BEEP.5.4 Triggering a discreet emergencyalarm (shutdown under duress)To do this, add 1 to the 1st digit of the access code.Example:- access code "123456", duress code "223456",- or access code "923456", duress code "023456",The LED changes from red to green to confirm the action.The alarm control unit emits a BEEP.The telephone transmitter calls from the3rd number programmed.The 1st and 2nd numbers are not called for the discreetemergency alarm.This function is used to let anyaggressor believe you have entered the right access codewhile triggering a discreet alarm (no audible signal) with yourtelephone transmitter, whether the system is shutdown oractivated.ON1Activation denied (e.g.open entry)Beep, beep, beep< 5sON ON1 2Beep, beep, beep5. Use with your simple keypadOKSOS+1+1Access codeAccess codeDuresscodeDuresscodeFor example, this function is used to activate the system evenif an entry remains open or if a product shows a defect (deadbattery, etc.).5.5 Triggering of an emergency alarmwith sirenPress and hold the SOS button for 2 seconds.The LED changes from red to green to confirmthe action.The alarm control unit emits a BEEP.The emergency alarm with siren triggers:- a call cycle from the transmitter to the programmednumbers (starting with the 1st number).- an audible signal from an associated siren.To stop an active emergency alarm with siren, enter the access codethen press OFF.5.6 Clearing defectsEach time the system is activated or deactivated, the alarm controlunit will inform you that an event (or defect) is stored by using aseries of beeps or a refusal to switch on. These events (intruderdetection, product defect, open entry, etc.) can be cleared so as notto be signalled by the control unit.The system must be off.If you do not have a touch screen keypad, you canclear defects by using the simple keypad:Ê Enter your access code.Ë Press and hold the button for 5 seconds.The LED changes from red to green to confirm the action.The alarm control unit emits a series of beeps, stops, then emitsone more beep.5.7 Disable audible beeps for the buttonPress and hold the button for 5 seconds untilthe green LED comes on.This function is used to trigger a call with yourtelephone transmitter to warn relatives that you are in a situationof distress. It also sets off the sirens with a specific tone.>2sOKSOS+1 2>5sOFFTo enable the beeps again, pressthe button for 5 seconds.>5s >5s