Setup-Eventsڼ Web setting page (Events)Digital Input[Logical Status (Sensor Type)]- Set according to the normal state of the electrical signal of the attached device. (Open / Close).1) N.O. (Normal Open): in case of the normal state is "open"2) N.C. (Normal Close): in case of the normal state is "close"[OK button] click this button to apply the changed setting values.Overview of setting "Event"- Define an action for which the event occurred.- Each of the supported features vary by model.- Event Types[Digital Input] when the Digital Input (DI) is detected, an event occurs. The detection status can be adjustedin detail as below.1) Active to inactive: when the detected state of the DI is changed into the non detected state, an eventoccurs.2) Inactive to active: when the non-detected state of the DI is changed into the detected state, an eventoccurs.3) Active level: when the detected state of the DI maintains, the event maintains.4) Inactive level: when the non-detected state of the DI maintains, the event maintains.