INSTALLATION (CONTINUED)111. Remove the screw holding on the connection cover.Remove the connection cover on the outdoor unit toaccess the connection area.3. Connect the wires to the housing and terminals onthe Control board individually according to the out-door unit Connection.INSTALLING THE INDOOR/OUTDOOR WIRE TO THE OUTDOOR UNIT FOR AC CONNECTIONThe Indoor/Outdoor wire is used to supply AC from the Indoor unit to the Outdoor unit. To install the indoor/outdoor wire,follow the procedures below.2. Route the indoor/outdoor wire into the opening onthe outdoor unit and through the wire holder. To con-nect to the wire holder, loosen the screw on the wireholder, insert the wires through, then tighten thescrew.Use the wire as shown below:Housing & Terminals on theoutdoor unit Housing BGRAYcolor of wirescolor of wiresBLACKGRAYBLACKHousing ABlackBrown Yellow/Green BlueBlackBrown Yellow/Green Blue BlueBlueY 1L 2TerminalsHousing & Terminals on theindoor unitMain PCB TerminalsY 1L 24. To connect wires, loosen the screw in the TerminalBlock and insert the correct wires like following fig-ure. Connect the Brown wire to the “L” connection,Yellow/Green wire to the “ ” connection, the Bluewire to “Y” connection, the Blue wire to “1” connec-tion and the Black wire to “2” connection. InsertHousing “A” and Housing “B” to connection.The used connection cable connected to indoor andoutdoor unit must be ;1) H07RN-F 3G1.5mm2 (NOT INCLUDED)2) H07RN-F 2G1.5mm2 (NOT INCLUDED)3) UL2464 AWG22 2G0.75mm2 (INCLUDED IN SET)BlueBlueBlackHousingAHousingBLY12Brown Yellow/Green2)1)3)ConnectionCable CoverClamp CordNOTES:• Make sure the Indoor unit’s AC cord is not connected toAC power when connecting the indoor/outdoor wire.• When connecting wires, make sure they are fully insert-ed and minimum copper wire is exposed. If they arenot, shorting, overheating, no operation, etc. may occur.• Be sure to comply with local codes on running a wirefrom the indoor to the outdoor unit.BrownYellow/GreenBlueBlueBlackConnectionCover