INSTALLATION (CONTINUED)7NOTES:• This appliance must be installed according to Nationalpower supply requirement.• If the supply cord is damaged, it must be replaced bythe manufacturer or its service agent or a similarly qual-ified person in order to avoid a hazard.• Make sure the Indoor unit’s AC cord is not connected toAC power when connecting the indoor/outdoor wire.• When connecting wires, make sure they are fully insert-ed and minimum copper wire is exposed. If they arenot, shorting, overheating, no operation, etc. may occur.• Be sure to comply with local codes on running a wirefrom the indoor to the outdoor unit.1. Open the connection cover on the indoor unit to ac-cess the connection area.Remove the ConnectionCover.• Loosen one screw for fixingthe Connection Cover.• Loosen one screw at theConnection Cover.• Remove the ConnectionCover.2. Fish the indoor/outdoor wire from the rear of the in-door unit through the front of the unit.For easier connection, make sure enough wire ispulled through the front.Use the wire as shown below:BrownYellow/GreenBlueBlueBlackINSTALLING THE INDOOR/OUTDOOR WIRE TO THE INDOOR UNIT FOR AC CONNECTIONThe Indoor/Outdoor wire is used to supply AC from the Indoor unit to the Outdoor unit. To install the indoor/outdoor wire,follow the procedures below.3. To connect wires, loosen the screw in the TerminalBlock and insert the correct wires like following fig-ure. Connect the Brown wire to the “L” connection,Yellow/Green wire to the “ ” connection, the Bluewire to “Y” connection, the Blue wire to “1” connec-tion and the Black wire to “2” connection.Blue Blue BlackLY 12Yellow/GreenBrownScrewConnection cover