INSTALLATION (CONTINUED)84. Connect the wires to the housing and terminals onthe control board individually according to the out-door unit connection.The used connection cable connected to indoor and out-door unit must be ;1) H07RN-F 3G1.5mm2 (NOT INCLUDED)2) H07RN-F 2G1.5mm2 (NOT INCLUDED)3) UL2464 AWG22 2G0.75mm2 (INCLUDED IN SET)Housing & Terminals on theoutdoor unit Housing BGRAYcolor of wirescolor of wiresBLACKGRAYBLACKHousing ABlackBrown Yellow/Green BlueBlackBrown Yellow/Green Blue BlueBlueY 1L 2TerminalsHousing & Terminals on theindoor unitMain PCB TerminalsY 1L 2HausingA1) 2) 3)2. Make sure the drain hose and copper tubing arewrapped with the rubber insulation. Using the tape,wrap the indoor/outdoor wire, copper tubing anddrain hose together.MOUNTING THE INDOOR UNITThe Indoor unit must be mounted before connecting the indoor/outdoor wire, drain hose and copper tubing. To mount,follow the procedures below:1. The tubing can be extended in 4 directions as shownbelow. No cutting is necessary for left/rear andright/rear tubing connections. If using left or right tub-ing connections, remove the plastic area with a hack-saw so pipes can go through.LeftTubingRightTubingRight/RearTubingLeft/RearTubingCAUTION:• Make sure the Indoor unit’s AC cord is not con-nected to AC power when performing these pro-cedures.• Be sure to comply with local codes on running awire from the indoor to the outdoor unit.• DO NOT LET THE INDOOR/OUTDOOR WIRECOME IN DIRECT CONTACT WITH THE TUB-ING OR HOSE!