Alarm Control Panel Installer Manual52Submenu SettingPATROL DISARM Set the disarming time period for the patrol user. If you set the time to 0,disarming is not allowed.ZONE IN TEST Set the time period for the test mode of zone. After this period, the zonereturns to ACTIVE.PROGRAM TIMETechnician Timer Program.Set the maximum time available for TEHCNICIAN to program the systemafter user authorization. Valid time from 01 to 10 hours.Press to return to the SYSTEM TIMING menu.Step 4Then you can press and to move to the next menu or press to exit from theInstaller Menu.SYSTEM TIMERS1.30After entering the Installer Menu, press and to scroll up and down until you reach theStep 1SYSTEM TIMERS menu. See Figure 1-27.System timerFigure 1-27Press to enter the programming mode.Step 2Press and to select the Timer that you want to configure, and then press .Step 3By pressing + 2, you can enter the EDITING mode for changing the description of timer.Configure the settings. See Table 1-24.Step 4Press and to alter the options. Press to confirm the setting and move to the nextsubmenu.Table 1-24 System timer settingsSubmenu SettingSTATEACTIVE: Timer enabled.ISOLATE: Timer enabled but temporarily locked.OFF: Timer disabled.TYPESTART/STOP: The timer applies to arming and disarming, access codeduration and LINK OUTPUT duration.STAR: The timer applies to arming only.STOP: The timer applies to disarming only.