Installation and maintenance manual22DAIKIN EKHHP(3/5)00AA2V3DAIKIN Hot water heat pump008.1423444_02 – 09/20155 x Operation, ParametersThe integrated Booster Heater (BOH) is also controlled in a fully-automatic manner by the controller integrated in the DAIKINEKHHP. The switching limits and switching time periods are de-fined in the parameter settings. If the Booster Heater (BOH) isswitched on, in the display of the controller, the icon appears.5.4.1 Display switching times1. Press the key. The current operating mode flashes.2. Use the and keys to select the operating mode to beprogrammed. The selected operating mode flashes.3. Use the key to confirm the selection. The first weekday "MON" is displayed.4. Use the and keys to select the weekday tobe programmed.5. Use the key to confirm the selection. The first switching time programmed for the selectedoperating mode is displayed.6. Use the and keys to move to the otherswitching times for this operating mode. Empty switchingtimes are not displayed.This key moves you back by one step.5.4.2 Programming switching times7. Hold the key pressed for 5 s.8. Use the key to select the switching time number.9. Use the and keys to set the starting time.10. By pressing the key, you can select the type ofswitching for this switching time number.11. Confirm the switching time and switching type using thekey (press briefly).12. Repeat steps 8 to 11 to program the other switching times orto change to the highest switching time of the current day(see step 6). Then continue with step 13 to completeprogramming.13. Hold the key pressed for 5 s. The switching time set is displayed, saved and all switch-ing times below that are also saved. All switching timesabove the current switching time are deleted. It automatically returns to step 6.5.4.3 Delete switching timeDelete individual switching timesDeleting one or more programmed switching times is carried outat the same time as saving the programmed switching times.The following table explains the procedure.For example:– At least 4 switching times were programmed for Monday.– Switching times 1 to 3 are set.– After the third switching time, the key (hold for 5 secs.)confirms the end of the programming.– The fourth switching time and, if there is one, the fifth switch-ing time will be deleted.If the DAIKIN EKHHP is in an "OFF" period, the tariffcontact HT/LT and SG can no longer be evaluated andthus have no influence on the operation of the instal-lation.Fig. 5-2 Display and programme switching times