X64-AN Quad User's Manual Sapera LT 81 Configuration of line/frame trigger parameters such as source (internal via the frame grabber/external via some outside event), electrical format (TTL, LVDS, OPTO-isolated), and signalactive edge or level characterization.CamExpert Example: Interfacing the JAI CV-A11The CamExpert utility is presented by using the example of interfacing the JAI CV-A11 progressivescan camera to the X64-AN Quad. The major steps covered are: Camera interfacing check list CamExpert interfacing outline JAI CV-A11 in free run exposure mode JAI CV-A11 in Partial Scan mode JAI CV-A11 in Edge Pre-select (trigger) mode JAI CV-A11 in Time Integration modeDownload the user's manual directly from the JAI web site [ http://www.jai.com/ ].Interfacing Outline Sapera and the X64-AN Quad device driver are installed. Check for an existing CCA file, distributed with Sapera, that will provide camera timingparameters. For the JAI CV-A11 the supplied file is "J_CV-A11.cca ". Check the Teledyne DALSA web site for a published application note with camera files[http://www.teledynedalsa.com/mv/support/support.aspx]. Connect the interface cables for video and serial port control to the camera. The X64-AN Quadprovides power to the camera via the video cable. Run the JAI CV-A11 camera control tool to set the camera in free run mode. This will simplifytesting the camera file timing parameters. The following screen image shows the control tool versionused within this document.Figure 41: JAI CV-A11 Control Tool Info