AKD 5000The bottom display line shows the text value that will beentered (saved) when acknowledgement is given [OK]. Change of group of numeric data valuesIf the chosen parameter represents a numericdata value, the chosen data value is changedby means of the [+/-] keys.50.0 HZ SETUP1FREQUENCY102 MOTOR POWER0.37 KWSETUP150.0 HZFREQUENCY102 MOTOR POWER0.55 KWSETUP1The chosen data value is indicated by the digit flashing.The bottom display line shows the data value that willbe entered (saved) when signing off with [OK]. Infinitely variable change of numericdata valueIf the chosen parameter represents a numeric datavalue, a digit is first selected by means of the [<>] keys.50.0 Hz SETUP1FREQUENCY130 START FREQUENCY09.0 HZThen the chosen digit is changed infinitely variablyby means of the [+/-] keys:50.0 Hz SETUP1FREQUENCY130 START FREQUENCY10.0 HZThe chosen digit is indicated by the digit flashing. Thebottom display line shows the data value that will beentered (saved) when signing off with [OK]. Changing of data value, step-by-stepCertain parameters can be changed step by stepor infinitely variably. This applies to Motor power(parameter 102), Motor voltage (parameter 103)and Motor frequency (parameter 104).The parameters are changed both as a group of numericdata values and as numeric data values infinitely variably. Read out and programming of indexed parametersParameters are indexed when placed in a rolling stack.Parameter 615 - 617 contain a historical log whichcan be read out. Choose the actual parameter, pressthe [CHANGE DATA] key and use the [+] and [-]keys to scroll through the log of values. During theread out line 4 of the display will flash.If a bus option is mounted in the drive, theprogramming of parameter 915 - 916 needs to becarried through in the following way:Choose the actual parameter, press the [CHANGEDATA] key and use the [+] and [-] keys to scroll throughthe different indexed values. To change the value ofthe parameter, select the indexed value and press the[CHANGE DATA] key. Using the [+] and [-] keys thevalue to be changed will flash. To accept the newsetting, press [OK], to abort, press [CANCEL]. Initialisation to factory settingThe frequency converter can be initialised tofactory settings in two ways.Initialisation by parameter 620- Recommended initialisation• Select parameter 620• Press [CHANGE]• Select "Initialisation"• Press the [OK] key• Cut off the mains supply and wait untilthe display turns off.• Reconnect the mains supply - the frequencyconverter is now reset.This parameter initialises all except:500 Serial communication address501 Baud rate for serial communication601-605 Operating data615-617 Fault logsManual initialisation• Disconnect from mains and wait until thedisplay turns off.MG.50.R3.02 -48