Status799RPM 7.83A 36.4kW0.00053.2%1(1)AutoHandOffRemoteLocal RampingStopRunningJogging...Stand-bye30bb037.121231 Operating mode. Refer to 8.3.2 Status Messages - OperatingMode.3 Operation status. Refer to 8.3.4 Status Messages - OperationStatus.2 Reference site. Refer to 8.3.3 Status Messages - ReferenceSite.Illustration 49: Status Display8.3.2 Status Messages - Operating ModeTable 37: Operating ModeOperatingmodeDescriptionOff The drive does not react to any control signal until [Auto On] or [Hand On] is pressed.Auto The drive requires external commands to execute functions. The start/stop commands are sent via the control ter-minals and/or the serial communication.Hand The navigation keys on the LCP can be used to control the drive. Stop commands, reset, reversing, DC brake, andother signals applied to the control terminals override local control.8.3.3 Status Messages - Reference SiteTable 38: Reference SiteReference site DescriptionRemote The speed reference is given from:• External signals.• Serial communication.• Internal preset references.Local The drive uses reference values from the LCP.Maintenance, Diagnostics, andTroubleshootingOperating Guide | VLT® AutomationDrive FC 302AQ275652476278en-000101 / 130R0709| 99Danfoss A/S © 2019.12