2 How to Programme2.1 Programming with MCT-10 SetupsoftwareThe frequency converter can be programmed from a PC viaRS-485 COM port by installing the MCT-10 Setup software.This software can either be ordered using code number130B1000 or downloaded from the Danfoss Web site: http://www.danfoss.com/BusinessAreas/DrivesSolutions/Software-download/ Please refer to manual MG.10.RX.YY.2.2 Local Control Panel (LCP)The following instructions are valid for the FC101 LCP. TheLCP is divided into four functional sections:A. Alphanumeric display.B. Menu key.C. Navigation keys and indicator lights (LEDs).D. Operation keys and indicator lights (LEDs).BackCom1-20 Motor Power[2] 0.12kW-0.16HPSetup 1AB11213 14 1511111098765432CDStatus MainMenuQuickMenuHandOnOKMenuOffResetAutoOnAlarmWarnOn130BB765.10A. Alpha Numeric DisplayThe LCD-display is back-lit with 2 alpha-numeric lines. Alldata is displayed on the LCP.A number of information can be read from the display:1 Parameter number and name.2 Parameter value.3 Set-up number shows the active set-up and the edit set-up.If the same set-up acts as both active and edit set-up, onlythat set-up number is shown (factory setting). When activeand edit set-up differ, both numbers are shown in thedisplay (Setup 12). The number flashing, indicates the editset-up.4 Motor direction is shown to the bottom left of the display –indicated by a small arrow pointing either clockwise orcounterclockwise.5 The triangle indicates if the LCP is in status, quick menu ormain menu.B. Menu KeyUse the menu key to select between status, quick menu ormain menu.C. Navigation keys and indicator lights (LEDs)6 Com led: Flashes when bus communication is communicating.7 Green LED/On: Control section is working.8 Yellow LED/Warn.: Indicates a warning.9 Flashing Red LED/Alarm: Indicates an alarm.10 [Back]: For moving to the previous step or layer in thenavigation structure11 Arrows [▲] [▼]: For maneuvering between parameter groups,parameters and within parameters. Can also be used forsetting local reference.12 [OK]: For selecting a parameter and for accepting changes toparameter settingsD. Operation keys and indicator lights (LEDs)13 [Hand on]: Starts the motor and enables control of thefrequency converter via the LCP.NOTEPlease note that terminal 27 Digital Input(5-12 Terminal 27 Digital Input) has coast inverse asdefault setting. This means that [Hand On] will notstart the motor if there is no 24V to terminal 27, soplease connect terminal 12 to terminal 27.14 [Off/Reset]: Stops the motor (off). If in alarm mode the alarmwill be reset.15 [Auto on]: Frequency converter is controlled either via controlterminals or serial communication.How to Programme VLT HVAC Basic Drive Programming Guide12 MG.18.B1.02 - VLT® is a registered Danfoss trademark22