0-32 Custom Readout Max ValueRange: Function:100.0 Custom-ReadoutUnit*[0.0 - 999999.99CustomRea-doutUnit]This parameter sets themax value to be shownwhen the speed of themotor has reached the setvalue for 4-14 Motor SpeedHigh Limit [Hz].0-37 Display Text 1Range: Function:0 * [0 - 0 ] In this parameter it is possible to write an individualtext string to be read via serial communication.Only used when running BACnet.0-38 Display Text 2Range: Function:0 * [0 - 0 ] In this parameter it is possible to write an individualtext string to be read via serial communication.Only used when running BACnet.0-39 Display Text 3Range: Function:0 * [0 - 0 ] In this parameter it is possible to write an individualtext string to be read via serial communication.Only used when running BACnet.3.1.4 0-4* LCPEnable, disable and password protect individual keys on theLCP.0-40 [Hand on] Key on LCPOption: Function:[0] Disable All Select Disabled [0] to avoid accidental start of thefrequency converter in Hand Mode.[1] * Enable All [Hand on] Key is enabled.0-42 [Auto on] Key on LCPOption: Function:[0] Disable All Select Disabled [0] to avoid accidental start of thefrequency converter from LCP.[1] * Enable All [Auto on] Key is enabled.0-44 [Off / Reset] Key on LCPOption: Function:[0] Disable All[1] * Enable All[2] Enable Reset Only Off is disabled.3.1.5 0-5* Copy / SaveCopy parameter settings between set-ups and to/from theLCP.0-50 LCP CopyOption: Function:[0] * No copy[1] All to LCP Copies all parameters in all set-ups from thefrequency converter memory to the LCPmemory. For service purposes it isrecommended to copy all parameters to theLCP after commissioning.[2] All fromLCPCopies all parameters in all set-ups from theLCP memory to the frequency convertermemory.[3] Size indep.from LCPCopies only the parameters that areindependent of the motor size. The latterselection can be used to programme severalfrequency converters with the same functionwithout disturbing motor data which arealready set.0-51 Set-up CopyOption: Function:[0] * No copy No function[1] Copy from setup 1 Copy from setup 1 to setup 2.[2] Copy from setup 2 Copy from setup 2 to setup 1.[9] Copy from FactorysetupCopy factory setting to programmingsetup (chosen in 0-11 Programming Set-up).3.1.6 0-6* Password0-60 Main Menu PasswordRange: Function:0 * [0.0 - 999.0 ] Define the password for access to the MainMenu via the [Main Menu] key. Setting value to0 disables the password-function.Parameters VLT HVAC Basic Drive Programming GuideMG.18.B1.02 - VLT® is a registered Danfoss trademark 233 3