16-09 Custom Readout0 CustomRea-doutUnit All set-ups FALSE -2 Int3216-1* Motor Status16-10 Power [kW] 0 kW All set-ups FALSE 1 Int3216-11 Power [hp] 0 hp All set-ups FALSE -2 Int3216-12 Motor Voltage 0 V All set-ups FALSE -1 Uint1616-13 Frequency 0 Hz All set-ups FALSE -1 Uint1616-14 Motor current 0 A All set-ups FALSE -2 Int3216-15 Frequency [%] 0 % All set-ups FALSE -2 N216-16 Torque [Nm] 0 Nm All set-ups FALSE -1 Int3216-17 Speed [RPM] 0 RPM All set-ups FALSE 67 Int3216-18 Motor Thermal 0 % All set-ups FALSE 0 Uint816-22 Torque [%] 0 % All set-ups FALSE 0 Int1616-26 Power Filtered [kW] 0 kW All set-ups FALSE 0 Int3216-27 Power Filtered [hp] 0 hp All set-ups FALSE -3 Int3216-3* Drive Status16-30 DC Link Voltage 0 V All set-ups FALSE 0 Uint1616-32 Brake Energy /s 0 kW All set-ups FALSE 0 Uint3216-33 Brake Energy /2 min 0 kW All set-ups FALSE 0 Uint3216-34 Heatsink Temp. 0 °C All set-ups FALSE 100 Uint816-35 Inverter Thermal 0 % All set-ups FALSE 0 Uint816-36 Inv. Nom. Current ExpressionLimit All set-ups FALSE -2 Uint3216-37 Inv. Max. Current ExpressionLimit All set-ups FALSE -2 Uint3216-38 SL Controller State 0 N/A All set-ups FALSE 0 Uint816-39 Control Card Temp. 0 °C All set-ups FALSE 100 Uint816-40 Logging Buffer Full [0] No All set-ups TRUE - Uint816-43 Timed Actions Status[0] Timed ActionsAuto All set-ups TRUE - Uint816-49 Current Fault Source 0 N/A All set-ups TRUE 0 Uint816-5* Ref. & Feedb.16-50 External Reference 0 N/A All set-ups FALSE -1 Int1616-52 Feedback[Unit] 0 ProcessCtrlUnit All set-ups FALSE -3 Int3216-53 Digi Pot Reference 0 N/A All set-ups FALSE -2 Int1616-54 Feedback 1 [Unit] 0 ProcessCtrlUnit All set-ups FALSE -3 Int3216-55 Feedback 2 [Unit] 0 ProcessCtrlUnit All set-ups FALSE -3 Int3216-56 Feedback 3 [Unit] 0 ProcessCtrlUnit All set-ups FALSE -3 Int3216-58 PID Output [%] 0 % All set-ups TRUE -1 Int1616-6* Inputs & Outputs16-60 Digital Input 0 N/A All set-ups FALSE 0 Uint1616-61 Terminal 53 Switch Setting [0] Current All set-ups FALSE - Uint816-62 Analog Input 53 0 N/A All set-ups FALSE -3 Int3216-63 Terminal 54 Switch Setting [0] Current All set-ups FALSE - Uint816-64 Analog Input 54 0 N/A All set-ups FALSE -3 Int3216-65 Analog Output 42 [mA] 0 N/A All set-ups FALSE -3 Int1616-66 Digital Output [bin] 0 N/A All set-ups FALSE 0 Int1616-67 Pulse Input #29 [Hz] 0 N/A All set-ups FALSE 0 Int3216-68 Pulse Input #33 [Hz] 0 N/A All set-ups FALSE 0 Int3216-69 Pulse Output #27 [Hz] 0 N/A All set-ups FALSE 0 Int3216-70 Pulse Output #29 [Hz] 0 N/A All set-ups FALSE 0 Int3216-71 Relay Output [bin] 0 N/A All set-ups FALSE 0 Int1616-72 Counter A 0 N/A All set-ups TRUE 0 Int3216-73 Counter B 0 N/A All set-ups TRUE 0 Int3216-75 Analog In X30/11 0 N/A All set-ups FALSE -3 Int3216-76 Analog In X30/12 0 N/A All set-ups FALSE -3 Int32Parameter Lists VLT® HVAC Drive FC 102236 Danfoss A/S © 03/2015 All rights reserved. MG11CE0255