Par. No. # Parameter description Default value 4-set-up Change during opera-tionConver-sion indexType15-0* Operating Data15-00 Operating Hours 0 h All set-ups FALSE 74 Uint3215-01 Running Hours 0 h All set-ups FALSE 74 Uint3215-02 kWh Counter 0 kWh All set-ups FALSE 75 Uint3215-03 Power-ups 0 N/A All set-ups FALSE 0 Uint3215-04 Over Temps 0 N/A All set-ups FALSE 0 Uint1615-05 Over Volts 0 N/A All set-ups FALSE 0 Uint1615-06 Reset kWh Counter [0] Do not reset All set-ups TRUE - Uint815-07 Reset Running Hours Counter [0] Do not reset All set-ups TRUE - Uint815-08 Number of Starts 0 N/A All set-ups FALSE 0 Uint3215-1* Data Log Settings15-10 Logging Source 0 2 set-ups TRUE - Uint1615-11 Logging Interval ExpressionLimit 2 set-ups TRUE -3 TimD15-12 Trigger Event [0] FALSE 1 set-up TRUE - Uint815-13 Logging Mode [0] Log always 2 set-ups TRUE - Uint815-14 Samples Before Trigger 50 N/A 2 set-ups TRUE 0 Uint815-2* Historic Log15-20 Historic Log: Event 0 N/A All set-ups FALSE 0 Uint815-21 Historic Log: Value 0 N/A All set-ups FALSE 0 Uint3215-22 Historic Log: Time 0 ms All set-ups FALSE -3 Uint3215-23 Historic Log: Date and Time ExpressionLimit All set-ups FALSE 0 TimeOfDay15-3* Alarm Log15-30 Alarm Log: Error Code 0 N/A All set-ups FALSE 0 Uint1615-31 Alarm Log: Value 0 N/A All set-ups FALSE 0 Int1615-32 Alarm Log: Time 0 s All set-ups FALSE 0 Uint3215-33 Alarm Log: Date and Time ExpressionLimit All set-ups FALSE 0 TimeOfDay15-34 Alarm Log: Setpoint 0.000 ProcessCtrlUnit All set-ups FALSE -3 Int3215-35 Alarm Log: Feedback 0.000 ProcessCtrlUnit All set-ups FALSE -3 Int3215-36 Alarm Log: Current Demand 0 % All set-ups FALSE 0 Uint815-37 Alarm Log: Process Ctrl Unit [0] All set-ups FALSE - Uint815-4* Drive Identification15-40 FC Type 0 N/A All set-ups FALSE 0 VisStr[6]15-41 Power Section 0 N/A All set-ups FALSE 0 VisStr[20]15-42 Voltage 0 N/A All set-ups FALSE 0 VisStr[20]15-43 Software Version 0 N/A All set-ups FALSE 0 VisStr[5]15-44 Ordered Typecode String 0 N/A All set-ups FALSE 0 VisStr[40]15-45 Actual Typecode String 0 N/A All set-ups FALSE 0 VisStr[40]15-46 Adj Freq Dr Ordering No. 0 N/A All set-ups FALSE 0 VisStr[8]15-47 Power Card Ordering No. 0 N/A All set-ups FALSE 0 VisStr[8]15-48 LCP ID Num. 0 N/A All set-ups FALSE 0 VisStr[20]15-49 SW ID Control Card 0 N/A All set-ups FALSE 0 VisStr[20]15-50 SW ID Power Card 0 N/A All set-ups FALSE 0 VisStr[20]15-51 Adj Freq Dr Serial No. 0 N/A All set-ups FALSE 0 VisStr[10]15-53 Power Card Serial Number 0 N/A All set-ups FALSE 0 VisStr[19]8.3.14 15-** FC InformationVLT® AQUA DriveInstruction Manual8 How to program the adjustable frequencydriveMG.20.M5.22 - VLT® is a registered Danfoss trademark 8-638