References312 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300Reading ParametersLabel Gone TimeoutThis feature sets the time after the last label segment is seen before the reader prepares for a newlabel. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require atrigger pull for each label that is readFollow these instructions to set this feature:1. Determine the desired setting in milliseconds.2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-ing zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.3. Go to page 93 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enterProgramming Mode.4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING.5. Scan the appropriate three alpha-numeric characters from the keypad in Appendix D,Keypad representing the duration which was determined in the steps above. You will heara two-beep indication after the last character.If you make a mistake before the last character, scan the CANCEL barcode toabort and not save the entry string. You can then start again at the begin-ning.6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit ProgrammingMode.This completes the procedure. See Table 40 for some examples of how to set this feature.Table 40. Timeout Setting ExamplesSTEP ACTION EXAMPLES1 Desired Setting 50ms 150ms 1800ms (1.8 sec.) 2550ms (2.55 sec.)2 Divide by 10 (and pad withleading zeroes) 005 015 180 2553 Scan ENTER/EXIT PROGRAMMING MODE4 Scan SELECT LABEL GONE TIMEOUT SETTING5 Scan Three Characters FromAppendix D, Keypad ‘0’, ‘0’ and ‘5’ ‘0’, ‘1’ and ‘5’ ‘1’, ‘8’ and ‘0’ ‘‘2’, ‘5’ and ‘5’6 Scan ENTER/EXIT PROGRAMMING MODE