Scanning FeaturesProduct Reference Guide 315Scanning Active TimeThis setting specifies the amount of time that the reader stays in scan ON state once the state isentered. The range for this setting is from 1 to 255 seconds in 1-second increments.Follow these instructions to set this feature:1. Determine the desired setting.2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20= 020, etc.3. Go to page 104 and scan the ENTER/EXIT PROGRAMMING MODE barcode toenter Programming Mode.4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING.5. Scan the appropriate three digits from the keypad in Appendix D, Keypad, that representthe duration which was determined in the steps above. You will hear a two-beep indica-tion after the last character.If you make a mistake before the last character, scan the CANCEL barcode toabort and not save the entry string. You can then start again at the begin-ning.6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit ProgrammingMode.This completes the procedure. See Table 42 for some examples of how to set this feature.Table 42. Scanning Active Time Setting ExamplesSTEP ACTION EXAMPLES1 Desired Setting 1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.) 255 Seconds (4.25 min.)2 Pad leading zero(es) 001 090 180 2553 Scan ENTER/EXIT PROGRAMMING MODE4 Scan SELECT SCANNING ACTIVE TIME SETTING5 Scan Three Characters FromAppendix D, Keypad ‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’6 Scan ENTER/EXIT PROGRAMMING MODE