Global Prefix Enter/Exit Programming ModeProduct Reference Guide 99Global Prefix/SuffixGlobal PrefixThis feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and SingleCable). It specifies the prefix that is added to beginning of label transmission.To specify the Global Prefix Character(s):1. Scan the Enter/Exit Programming Mode bar code.2. Scan the bar code Set Global Prefix below. Cover any unused bar codes toensure the scanner reads only the bar code you intend to scan.3. Scan the appropriate characters/digits from the Alpha-Numeric Keypad onpage 295 that represent the hex designation for the desired character(s).The ASCII Character Set and their corresponding Hex Values are availablein the inside back cover of this manual. ASCII parameters must be input byscanning a pair of hexadecimal digits for each character. Thus, to set atwo-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and‘2’ must be scanned. The selectable range for this option is any hex valuefrom 00 to FF. Up to 20 hex pairs can be designated.NOTETo specify “No Global Prefix,” scan 00.4. If designating the full 20 hex pairs, the scanner will exit ProgrammingMode when the appropriate amount of digits have been scanned. If desig-nating less than 20 hex pairs, you can end the programming sequenceearly by scanning the Terminate Sequence bar code.5. Complete the programming sequence by scanning the Enter/Exit Pro-gramming Mode bar code.031D(CR)Set Global Prefix00000(CR)Terminate SequenceDEFAULT Default setting for this feature is:00 - No Global Prefix