Micro QR Code Length Control Enter/Exit Programming ModeProduct Reference Guide 277Micro QR Code Length 1, Length 2 Programming InstructionsIf Micro QR Code Length Control is set to Fixed-Length decoding, this featurespecifies Micro QR Code first fixed length. If Micro QR Code Length Control isset to Variable-Length decoding, this feature specifies the minimum labellength.NOTELength 1 is the minimum label length if in variable lengthmode, or the first fixed length if in fixed length mode. Length 2is the maximum label length if in variable length mode, or thesecond fixed length if in fixed length mode. Length includesthe bar code's data characters only. Any value > 3700 will beconsidered to be 3700.To set this feature:1. Scan the ENTER/EXIT Programming Mode bar code.2. Scan the bar code, Set Aztec Length 1 on page 280 or Set Micro QR CodeLength 2 on page 277 below. You’ll need to cover any unused bar codeson this and the facing page to ensure that the scanner reads only the barcode you intend to scan.3. Scan the appropriate digits from the Alpha-Numeric Keypad in Appendix Cthat represent the desired label length. The selectable range for thisoption is 0001 to 3700. Pad all numbers with leading zeros to yield a four-digit entry (0001-3700).4. Complete the programming sequence by scanning the ENTER/EXIT Pro-gramming Mode bar code.Default setting for this feature = 0001042B(CR)Set Micro QR Code Length 1042C(CR)Set Micro QR Code Length 2Default setting for this feature = 0E74