Enter/Exit Programming Mode110 PowerScan™ PD9330/PBT9300/PM9300Code 128 Length ControlThis feature specifies either variable length decoding or fixed length decod-ing for the Code 128 symbology.Variable Lenght. For variable length decoding, a minimum and maximumlength may be set.Fixed Lenght. For fixed length decoding, two different lengths may be set.DEFAULT$ Code 128 Length Control = Variable Length$CC LC (CR)Code 128 Length Control = Fixed LengthCode 128 Set Length 1Specifies one of the bar code lengths for Code 128 Length Control. Length 1is the minimum label length if in Variable Length Mode, or the first fixedlength if in Fixed Length Mode. Length includes the bar code’s data charac-ters only. The length can be set from 1 to 80 characters.Table 6 provides some examples for setting Length 1. See page 266 fordetailed instructions on setting this feature.Table 6. Code 128 Length 1 Setting ExamplesSTEP ACTION EXAMPLES1 Desired Setting 01 Character 07 Characters 15 Characters 80 Characters2 Scan ENTER/EXIT PROGRAMMING MODE3 Scan SELECT CODE 128 LENGTH 1 SETTING4 Scan Two Characters FromAppendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘8’ AND ‘0’5 Scan ENTER/EXIT PROGRAMMING MODE$CC8L1Select Code 128 Set Length 1 SettingTo configure this feature, scan the ENTER/EXIT barcode above, then the bar code at left followed by dig-its from the Alphanumeric characters in Appendix D,Keypad representing your desired character(s). Endby scanning the ENTER/EXIT bar code again.Make a mistake? Scan the CANCEL bar code to abortand not save the entry string. You can then startagain at the beginning.~CANCELDEFAULT 01 = Length 1 is 1 Character