References276 PowerScan™ PD9330/PBT9300/PM9300Reading ParametersGood Read LED DurationThis feature specifies the amount of time that the Good Read LED remainson following a good read. The good read LED on time can be set within arange of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in100ms increments.Follow these instructions to set this feature:1. Determine the desired setting in milliseconds. A setting of 0 means thatthe good read LED stays on until the next time the trigger is pulled.2. Divide the desired setting by 10 (setting is in 100ms increments). Padthe result with leading zeroes to yield three digits. For example: 0 =000, 5 = 000, 20 = 020, etc.3. Go to page 70 and scan the ENTER/EXIT PROGRAMMING MODE bar codeto enter Programming Mode.4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.5. Scan the appropriate three digits from the keypad in Appendix D, Key-pad representing the duration which was determined in the stepsabove. You will hear a two-beep indication after the last character.If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start againat the beginning.6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-ming Mode.This completes the procedure. See Table 43 for some examples of how toset this feature.Table 43. Good Read LED Duration Setting ExamplesSTEP ACTION EXAMPLES1 Desired SettingGood Read LEDstays on untilnext trigger pull(00)20ms 150ms 2550ms (2.55 sec.)2 Divide by 10 (and pad withleading zeroes) 000 002 015 2553 Scan ENTER/EXIT PROGRAMMING MODE4 Scan SELECT GOOD READ LED DURATION SETTING5Scan Three CharactersFrom Appendix D,Keypad‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘2’ ‘0’, ‘1’ and ‘5’ ‘2’, ‘5’ and ‘5’6 Scan ENTER/EXIT PROGRAMMING MODE