174 PowerScan™ PD9330/PBT9300/PM9300Codablock F Length ControlThis feature specifies either variable length decoding or fixed length decod-ing for the Codablock F symbology.Variable Length. For variable length decoding, a minimum and maximumlength may be set.Fixed Length. For fixed length decoding, two different lengths may be set.DEFAULTCodablock F Length Control = Variable LengthCodablock F = Fixed LengthCodablock F Set Length 1This feature specifies one of the bar code lengths for Codablock F LengthControl. Length 1 is the minimum label length if in Variable Length Mode, orthe first fixed length if in Fixed Length Mode. Length includes the bar code’sdata characters only.The length can be set from 003 to 255 characters. See "Set Length 1" onpage 239 for more detailed programming instructions.Table 22. Codablock F Length 1 Setting ExamplesSTEP ACTION EXAMPLES1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters2 Scan ENTER/EXIT PROGRAMMING MODE3 Scan SELECT CODE 93 LENGTH 1 SETTING4 Scan Two Characters FromAppendix D, Keypad ‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’5 Scan ENTER/EXIT PROGRAMMING MODESelect Codablock F Set Length 1 SettingTo configure this feature, scan the ENTER/EXIT bar code above, then the bar code atleft followed by digits from the Alphanu-meric characters in Appendix D, Keypadrepresenting your desired character(s). Endby scanning the ENTER/EXIT bar codeagain.Make a mistake? Scan the CANCEL bar code to abortand not save the entry string. You can then startagain at the beginning. CANCELDEFAULT 003 = Length 1 is 3 Characters