123Viewing Events in the SELWhen the SEL Viewer is opened (see Figure 45), the first page of events is loaded from the log anddisplayed. To view the remaining events you are provided with a series of buttons along the bottomof the screen. You can use the key to access the screen buttons.Acronym DescriptionRID Record IDRT Record TypeTS Time StampGID Generator IDER Event Message Format RevisionST Sensor TypeSN Sensor NumberEDIR Event Dir and Event TypeED1 Event Data 1ED2 Event Data 2ED3 Event Data 3MID Manufacturer ID 1OEM OEM defined 2Figure 45. SEL Viewer, Hex Display Mode1 Used when displaying OEM SEL Records Type C0h-DFh2 Used when displaying OEM SEL Records Type C0h-DFh and E0h-FFh