3-16 Service ManualSensor Test (high capacity output stacker)1. Select Sensor Test from OUTPUT BIN TESTS.2. Select Output Bin x (x=number of the output option to be tested).The following screen is displayed:HC Bin x TP=OPpassThru=Open Full=Open NearFull=Open• TP—High-capacity top position sensor• passThru—High-capacity pass thru sensor• Full—High-capacity bin full sensor (lower part of dual sensor)• NearFull—High-capacity bin near full sensor (upper part of dual sensor)3. Manually actuate each of the sensors of the high-capacity stacker, and the display by each sensor togglesfrom Open to Closed.4. Press Back ( ) or Stop ( ) to exit the test.Sensor Tests (5-bin mailbox)1. Select Sensor Tests from OUTPUT BIN TESTS.2. Select Output Bin x (x=number of the output option to be tested).The following screen is displayed:Output Bin xP1=OP P2=OP L=NL• passThru—5-bin mailbox pass thru sensor shows Open or Closed• mailboxEmpty—5-bin mailbox empty sensor shows Normal for a normal level, NearFull for nearly full,and Full for full.3. Manually actuate each of the sensors of the 5-bin mailbox,. The pass thru sensor will indicate Open orClosed and the empty sensor (mailboxEmpty) indicates Normal, NearFull, or Full.4. Press Back ( ) or Stop ( ) to exit the test.Diverter TestThis test verifies the functioning of each of the 5-bin mailbox output media diverters. If more than one 5-binmailbox is installed, all installed diverters or tested.To run the Diverter Test, select Diverter Test from the OUTPUT BIN TESTS. The test runs once and stops.