192 Brocade Adapters Installation and Reference Manual53-1002144-01Fibre Channel standards compliance5Environmental and power requirementsThis section provides environmental and power specifications for the stand-up and mezzanineHBAs.Stand-up HBAsThe following table provides environmental and power specifications for the stand-up HBAs.Mezzanine HBAsThe Brocade 804 mezzanine adapter conforms to environmental and power specifications for thesupported blade servers and blade system enclosures where they install. Refer to thedocumentation provided for these products for information. Also refer to “Server blades and bladesystem enclosures (mezzanine adapters)” on page 11.Fibre Channel standards complianceBrocade adapters meet or exceed the Fibre Channel standards for compliance, performance, andfeature capabilities as defined in the Brocade standards compliance list. This information isavailable through links under the Solutions and Technology heading on the Brocade website atwww.brocade.com.Regulatory complianceThis section provides international regulatory compliance notices for the Brocade adapters.Stand-up adaptersThe regulatory statements in this section pertain to the following stand-up adapters:• 415 HBATABLE 29 Environmental and power requirementsProperty RequirementAirflow None required.Operating Temperature (dry bulb) 0°C to 55°C (32°F to 131°F)Operating Humidity 5% to 93%(relative-noncondensing)Nonoperating Temperature -43°C to 73°C (-40°F to 163°F)(dry bulb)Nonoperating Humidity 5% to 95%(relative-noncondensing)Power Dissipation 6.3WMaximum not including SFP.Operating Voltage Per PCIe 2.0 specifications