Foreign Configuration Not Found In Error MessageError Message: The foreign configuration message is present during POST but noforeign configurations are present in the foreign view page in . All virtual disks are in an optimal state.CorrectiveAction:Corrective Action: Ensure all your PDs are present and all VDs are in optimal state. Clear theforeign configuration using or Dell OpenManage Server Administrator StorageManagement.CAUTION: The physical disk goes to Ready state when you clear the foreign configuration.If you insert a physical disk that was previously a member of a virtual disk in the system, andthat disk’s previous location has been taken by a replacement disk through a rebuild, you mustmanually remove the foreign configuration flag of the newly inserted disk.Previous Configuration Cleared Or Missing Error MessageError Message: Previous configuration(s) cleared or missing. Importingconfiguration created on XX/XX XX.XX. Press any key tocontinue, or ’C’ to load the configuration utility.Probable Cause: The message indicates that the controller and physical disks have different configurations.CorrectiveAction:You can use the BIOS Configuration Utility ( ) to clear the foreign configuration.Invalid SAS Topology Detected Error MessageError Message: Invalid SAS topology detected. Please check your cableconfigurations, repair the problem, and restart your system.Probable Cause: The SAS cables for your system are improperly connected.CorrectiveAction:Check the cable connections and fix problems if any. Restart the system.Multibit ECC Errors Detected Error MessagesError Message: NOTE: The following error is specific to the PERC H710 controller only.Multibit ECC errors were detected on the RAID controller. Ifyou continue, data corruption can occur. Contact technicalsupport to resolve this issue. Press 'X' to continue or elsepower off the system, replace the controller and reboot.OrMultibit ECC errors were detected on the RAID controller. TheDIMM on the controller needs replacement. If you continue, datacorruption can occur. Press 'X' to continue or else power offthe system, replace the DIMM module, and reboot. If you havereplaced the DIMM please press 'X' to continue.76