Solving Problems: Dell OptiPlex GX260 Systems User's GuideHard-disk controller failure— The hard drive failed initialization.● Run the Dell Diagnostics.● See "Drive Problems" for troubleshooting suggestions.Hard-disk drive failure— The hard drive failed initialization.● Run the Dell Diagnostics.● See "Drive Problems" for troubleshooting suggestions.Hard-disk drive read failure— The hard drive failed initialization.● Run the Dell Diagnostics.● See "Drive Problems" for troubleshooting suggestions.Invalid configuration information - please run SETUP program— The computerconfiguration information does not match the hardware configuration. Enter system setupand correct the computer configuration information.Keyboard failure— A cable or connector may be loose, or the keyboard or keyboard/mouse controller may be faulty. See "Keyboard Problems."Memory address line failure at address, read value expecting value— A memorymodule may be faulty or improperly seated. Reinstall the memory modules and, ifnecessary, replace them. See "Memory Problems" for additional troubleshootingsuggestions.Memory allocation error— The software you are attempting to run is conflicting with theoperating system, another program, or a utility.1. Turn off the computer, wait 30 seconds, and then restart the computer.2. Try to run the program again.3. If the error message still appears, see the software documentation for additionaltroubleshooting suggestions.Memory data line failure at address, read value expecting value— A memorymodule may be faulty or improperly seated. Reinstall the memory modules and, ifnecessary, replace them. See "Memory Problems" for additional troubleshootingsuggestions.Memory double word logic failure at address, read value expecting value— Amemory module may be faulty or improperly seated. Reinstall the memory modules and,if necessary, replace them. See "Memory Problems" for additional troubleshootingsuggestions.http://support.dell.com/support/edocs/systems/opgx260/en/ug/solvprob.htm (13 of 30) [10/25/2007 1:44:24 PM]