594 Dell PowerConnect 55xx Systems User Guide– Initiators/Targets — The IP address and TCP port used by eachinitiator and target in the session is displayed.Displaying iSCSI Sessions Using CLI CommandsThe following table summarizes the CLI commands for displaying iSCSIsessions.The following is an example of the CLI commands:Table 20-3. iSCSI CLI CommandsCLI Command Descriptionshow iscsi sessions[detailed]Displays iSCSI sessionsconsole(config)# show iscsi sessionsTarget: iqn.1993-11.com.disk-vendor:diskarrays.sn.45678-------------------------------------------------------------Initiator: iqn.1992-04.com.os-vendor.plan9:cdrom.12ISID: 11Initiator: iqn.1995-05.com.os-vendor.plan9:cdrom.10ISID: 222--------------------------------------------------------------Target: iqn.103-1.com.storage-vendor:sn.43338.storage.tape:sys1.xyz--------------------------------------------------------------Initiator: iqn.1992-04.com.os-vendor.plan9:cdrom.12ISID: 44Initiator: iqn.1995-05.com.os-vendor.plan9:cdrom.10ISID: 65--------------------------------------------------------------console# show iscsi sessions detailedTarget: iqn.1993-11.com.disk-vendor:diskarrays.sn.45678--------------------------------------------------------------Session 1:---------Initiator: iqn.1992-04.com.os-vendor.plan9:cdrom.12.storage:sys1.xyzUP Time: 02:10:45 (DD:HH:MM)Time for aging out: 10 minISID: 11Initiator IP Address Initiator TCP Port Target IP Address Target IP Port-------------------- ----------------- ---------------- -------------172.16.1.3 49154 172.16.1.20 3001172.16.1.3 49154 172.16.1.20 30011172.16.1.3 49154 172.16.1.20 300130001Initiator: iqn.1995-05.com.os-vendor.plan9:cdrom.10Status: ActiveUP Time: 00:04:50 (DD:HH:MM)Time for aging out: 2 minISID: 22