PowerConnect B-Series FCX Configuration Guide 9353-1002266-01Viewing information about software licenses 4Viewing software packages installed in the deviceUse the show version command to view the software packages that are currently installed in thedevice.NOTEThe software package name is not the same as the license name.Table 20 lists the supported software packages.TABLE 20 Software packagesProduct Software package name License needed?PowerConnect B-SeriesFCXBASE_SOFT_PACKAGE NoFCX_FULL_ROUTER_SOFT_PACKAGE NoFCX_ADV_ROUTER_SOFT_PACKAGE YesPowerConnect#show versionCopyright (c) 1996-2010 Brocade Communications Systems, Inc.UNIT 1: compiled on Mar 30 2010 at 18:39:20 labeled as FCXR07000b1(5245400 bytes) from Secondary FCXR07000b1.binSW: Version 07.0.00b1T7f3Boot-Monitor Image size = 369286, Version:07.0.01T7f5 (grz07001)HW: Stackable FCX624SF==========================================================================UNIT 1: SL 1: FCX-24GS 24-port Management ModuleSerial #: PR320400289license: FCX_adv_router_soft_package (lid: rtihfjffhno)P-ENGINE 0: type DB10, rev 01==========================================================================UNIT 1: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)==========================================================================800 MHz Power PC processor 8544E (version 33/0022) 400 MHz bus65536 KB flash memory256 MB DRAMMonitor Option is onSTACKID 1 system uptime is 16 hours 35 minutes 25 secondsThe system : started=warm start reloaded=by "reload"