Icon Description Condition Corrective actionHard driveindicatorThe indicator flashes amberif there is a hard drive error.Check the System Event Log to determinethe hard drive that has an error. Run theappropriate Online Diagnostics test. Restartthe system and run embedded diagnostics(ePSA). If the hard drives are configured in aRAID array, restart the system and enter thehost adapter configuration utility program.ElectricalindicatorThe indicator flashes amberif the system experiences anelectrical error (for example,voltage out of range, or afailed power supply unit(PSU) or voltage regulator).Check the System Event Log or systemmessages for the specific issue. If it is dueto a problem with the PSU, check the LEDon the PSU. Reseat the PSU. If the problempersists, see the Getting help section.TemperatureindicatorThe indicator flashes amberif the system experiences athermal error (for example,the ambient temperature isout of range or fan failure).Ensure that none of the followingconditions exist:• A cooling fan has been removed or hasfailed.• System cover, cooling shroud, EMI fillerpanel, memory module blank, or backfiller bracket is removed.• Ambient temperature is too high.• External airflow is obstructed.See the Getting help section.MemoryindicatorThe indicator flashes amberif a memory error occurs.Check the system event log or systemmessages for the location of the failedmemory. Reseat the memory module. Ifthe problem persists, see the Getting helpsection.PCIe indicator The indicator flashes amberif a PCIe card experiencesan error.Restart the system. Update any requireddrivers for the PCIe card. Reinstall the card.If the problem persists, see the Getting helpsection.NOTE: For more information onsupported PCIe cards, see theExpansion card installation guidelinessection.Related LinksGetting helpExpansion card installation guidelines24