Table 64. Configuration validation error (continued)Error Description Possible cause andrecommendations ExampleComm Error A configuration element is not respondingto iDRAC using the management interfacewhile running an inventory check.System managementsideband communicationComm Error: Backplane 2Unplug AC Power, reseatthe element and replacethe element if the problempersists.Error messagesThis section describes the error messages displayed on the screen during POST or captured in the system event log (SEL)/LifeCycle (LC) log.Table 65. Error message HWC8010Error code HWC8010Message The System Configuration Check operation resulted in the following issue involving the indicatedcomponent typeArguments Riser, floating card (fPERClike BOSS), backplane, processor, cable, or other componentsDetailed Description The issue identified in the message is observed in the System Configuration Check operation.RecommendedResponse ActionDo the following and retry the operation:1. Disconnect the input power.2. Check for proper cable connection and component placement. If the issue persists, contact theservice provider.Category System Health (HWC = Hardware Config)Severity CriticalTrap/EventID 2329Table 66. Error message HWC8011Error code HWC8011Message The System Configuration Check operation resulted in multiple issues involving the indicated componenttypeArguments Riser, floating card (fPERClike BOSS), backplane, processor, cable, or other componentsDetailed Description Multiple issues are observed in the System Configuration Check operation.RecommendedResponse ActionDo the following and retry the operation:1. Disconnect the input power.2. Check for proper cable connection and component placement. If the issue persists, contact theservice provider.Category System Health (HWC = Hardware Config)Severity CriticalMinimum to POST and system management configuration validation 61