8System MessagesError MessagesError Message DescriptionAddress mark notfoundThe BIOS found a faulty disk sector or could not find a particular disk sector.Alert! Previousattempts at bootingthis system havefailed at checkpoint[nnnn]. For help inresolving thisproblem, please notethis checkpoint andcontact DellTechnical Support.The system failed to complete the boot routine three consecutive times for the same error.Contact Dell and report the checkpoint code (nnnn) to the support technician.Alert! Securityoverride Jumper isinstalled.The MFG_MODE jumper has been set and AMT Management features are disabled until it isremoved.Attachment failed torespondThe floppy or hard-drive controller cannot send data to the associated drive.Bad command or filenameEnsure that you have spelled the command correctly, put spaces in the proper place, and usedthe correct pathname.Bad error-correctioncode (ECC) on diskreadThe floppy or hard-drive controller detected an uncorrectable read error.Controller has failed The hard drive or the associated controller is defective.Data error The floppy or hard drive cannot read the data. For the Windows operating system, run thechkdsk utility to check the file structure of the floppy or hard drive. For any other operatingsystem, run the appropriate corresponding utility.Decreasing availablememoryOne or more memory modules may be faulty or improperly seated. Re-install the memorymodules and, if necessary, replace them.Diskette drive 0 seekfailureA cable may be loose or the system configuration information may not match the hardwareconfiguration.Diskette read failure The floppy disk may be defective or a cable may be loose. If the drive access light turns on, trya different disk.81