Error Code Message InformationDetails Power supplies should be of the same input type and power rating.Action Install matched power supplies and review this manual for properconfiguration.PSU1201 Message Power supply redundancy is lost.Details The power supply tries to operate in a degraded state. SystemPerformance and power redundancy may be degraded or lost.Action Check input power. Reinstall the power supply. If the issue persists,see Getting Help.PSU1204 Message The power supplies are not redundant. Insufficient resources tomaintain normal operations.Details The current power operational mode is non-redundant because of apower supply exception, a power supply inventory change, or asystem power inventory change.Action Check the event log for power supply failures. Review systemconfiguration and power consumption.PWR1004 Message The system performance degraded because power capacity haschanged.Details The system may power down or operate in a performance degradedstate.Action Check the event log for power supply failures. Review systemconfiguration and power consumption and upgrade or install powersupplies accordingly.PWR1005 Message The system performance degraded because the user-defined powercapacity has changed.Details The user-defined power settings have affected system operation.Action If unintended, review system configuration changes and powerpolicy.PWR1006 Message The system halted because system power exceeds capacity.Details The system halted because system power exceeds capacity.Action Review system configuration, upgrade power supplies or reducesystem power consumption.RFM1008 Message Failure detected on Removable Flash Media <name>.95