116 Script CommandsAutoconfigure Storage Array Hot SparesThis command automatically defines and configures the hot spares in astorage array. You can run this command at any time. This command providesthe best hot spare coverage for a storage array.SyntaxautoConfigure storageArray hotSparesParametersNone.NOTE: When you run the autoconfigure storageArray hotSpares command, theRAID controller module firmware determines the number of hot spares to createbased on the total number and type of physical disks in the storage array.diskGroupWidth Number of physical disks in a disk groupin the storage array. For informationabout the number of physical disks thatyou can use in a disk group, see"Enclosure Loss Protection" on page 52.diskGroupCount Number of disk groups in the storagearray. Use integer values.virtualDisksPerGroupCount Number of equal-capacity virtual disksper disk group. Use integer values.hotSpareCount Number of hot spares in the storage array.Use integer values. For information abouthot spares, see "Assigning Global HotSpares" on page 59.segmentSize Amount of data (in kilobytes) that theRAID controller module writes on a singlephysical disk in a virtual disk beforewriting data on the next physical disk.Valid values are 8, 16, 32, 64, 128, 256, or512. For information about thesegmentSize parameter, see "Using theAuto Configure Command" on page 53.Parameter Description