Ensure that you follow the Safety instructions.Steps1. Align the slots on the power interposer board (PIB) with the hooks on the power supply unit (PSU)cage and slide the PIB until it snaps into place.2. Route the power cables through the securing clips as applicable, and connect the power cables tothe system board.Next steps1. Install the cooling shroud.2. Install the PSUs or PSU blank.3. Follow the procedure listed in After working inside your system.Related TasksInstalling the cooling shroudInstalling a redundant AC power supply unitInstalling the power supply unit blankSystem batteryReplacing the system batteryPrerequisites1. Ensure that you follow the Safety instructions.2. Follow the procedure listed in Before working inside your system.3. Remove the cooling shroud.4. Keep the plastic scribe ready.WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace thebattery only with the same or equivalent type recommended by the manufacturer. For moreinformation, see the safety information that shipped with your system.CAUTION: Many repairs may only be done by a certified service technician. You should onlyperform troubleshooting and simple repairs as authorized in your product documentation, or asdirected by the online or telephone service and support team. Damage due to servicing that isnot authorized by Dell is not covered by your warranty. Read and follow the safety instructionsthat came with the product.NOTE: This is a Field Replaceable Unit (FRU). Removal and installation procedures must beperformed only by Dell certified service technicians.Steps1. Locate the battery socket. For more information, see System board jumpers and connectors.CAUTION: To avoid damage to the battery connector, you must firmly support the connectorwhile installing or removing a battery.2. Use a plastic scribe to pry out the system battery as shown in the following illustration:118