Video specificationsVideo SpecificationVideo type Integrated Matrox G200Video memory 16 MB sharedExpanded operating temperatureNOTE: When operating in the expanded temperature range, system performance may be impacted.NOTE: When operating in the expanded temperature range, ambient temperature warnings may bereported on the LCD and in the System Event Log.ExpandedoperatingtemperatureSpecifications≤ 10% of annualoperating hours5°C to 40°C at 5% to 85% RH with 26°C dew point.NOTE: Outside the standard operating temperature (10°C to 35°C), the systemcan operate down to 5°C or up to 40°C for a maximum of 10% of its annualoperating hours.For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulbtemperature by 1°C per 175 m above 950 m (1°F per 319 ft).≤ 1% of annualoperating hours–5°C to 45°C at 5% to 90% RH with 26°C dew point.NOTE: Outside the standard operating temperature (10°C to 35°C), the systemcan operate down to –5°C or up to 45°C for a maximum of 1% of its annualoperating hours.For temperatures between 40°C and 45°C, de-rate maximum allowable dry bulbtemperature by 1°C per 125 m above 950 m (1°F per 228 ft).ExpandedOperatingTemperatureRestrictions• The operating temperature specified is for a maximum altitude of 3048 m(10,000 ft).• Non-redundant power supply units are not supported.• Cabled power supply units are not supported.• Non Dell qualified peripheral cards and/or peripheral cards greater than 25 Ware not supported.• Internal Tape backup drive (TBU) is not supported.• Do not perform a cold startup below 5°C.• Enable processor performance degrade.165