M-Max Series adjustable frequency driveMN04020002E For more information visit: www.eaton.com 5February 2010Table 2: General Rated Operational DataTechnical data Unit ValueGeneralStandards and regulations EMC: IEC/EN 61800-3,Safety: IEC/EN 61800-5, UL 508CCertifications and manufacturer’sdeclarations on conformityEMC: CE, CB, c-TickSafety: CE, CB, UL, cUL, phenum ratedProduction quality RoHS, ISO 9001Climatic proofing < 95%, average relative humidity,noncondensing (EN 50178)Air qualityChemical vapors IEC 721-3-3: Device in operation, Class 3C2Mechanical particles IEC 721-3-3: Device in operation, Class 3S2Ambient temperatureOperation ºC –10 to +50 Storage ºC –40 to +70Installation altitude H 0 – 1000m above sea level, over 1000m with 1%power reduction per 100m, maximum 2000m,at maximum +50ºC ambient temperature.2000m maximum for corner grounded device,4500m for non-corner grounded deviceMounting position Vertical (± 90 degrees lateral rotation)Protection type IP20Busbar tag shroud BGV A3 (VBG4, finger and back-of-hand safe)Overvoltage category/degree ofpollution—Mechanical shock resistance IEC 68-2-27Storage and transport: 15g, 11 ms(in the packaging)UPS drop test (for applicable UPS weights)Vibration EN 60068-2-63 – 150 Hz, oscillation amplitude 1 mm (Peak)at 3 – 15.8 Hz, maximum acceleration amplitude 1gat 15.8 – 150 HzEmitted interference with internal EMCfilter (maximum motor cable length)C2: Class A in 1st environment (residential area withcommercial utilization)C3: Class A in 2nd environment (Industrial)MMX11 C2 (5m), C3 (30m)MMX12, MMX32 C2 (5m), C3 (30m)MMX34 C2 (5m), C3 (30m)Power SectionRated operational voltage at 50/60 Hz ±10 %MMX11 Ue 1 AC 115V (110V – 15% ... 120V + 10%)MMX12 Ue 1 AC 230V (208V – 15% ... 240V + 10%)MMX32 Ue 3 AC 230V (208V – 15% ... 240V + 10%)MMX34 Ue 3 AC 400V (380V – 15% ... 480V + 10%)