Eaton M-Max series manuals
M-Max series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Writing Conventions
- Input Supply Voltages
- Notes on the Second MMX Upgrade
- M-Max Series
- Checking the Delivery
- Nameplate Rating Data
- Catalog Number Selection
- Examples
- General Rated Operational Data
- Power Connection Voltages
- Description of the M-Max
- Block Diagram, Elements of M-Max Frequency Inverters
- Selection Criteria
- Proper Use
- Storage
- Introduction
- Electrical Power Network
- Safety and Switching
- EMC Measures
- Motor and Application
- Example of a Motor Ratings Plate
- Bypass Motor Control (Example)
- Air-Cooling Space
- Mounting Dimensions
- Mounting Rail Conforming with IEC/EN 60715
- EMC Installation
- EMC-Compliant Setup (Example: M-Max)
- Electrical Installation
- Three-Phase Input Connection
- Connection in Power Section
- Screened Connection Cable
- Arrangement and Size of the Connection Terminals
- Position of Control Signal Terminals
- Control Signal Terminals Assignments and Designations
- Factory-Set Control Terminal Functions
- Control Signal Terminals (Digital and Analog Inputs/Outputs)
- Analog Output AO (Connection Examples)
- Digital Inputs with External Supply Voltage (Negative Logic, Sink Type)
- with Suppressor Circuit
- Two-Wire RS485 Connection
- MMX11...N_ Block Diagram
- MMX12...F_ Block Diagram
- MMX32, MMX34 and MMX35 Block Diagram
- Commissioning Checklist
- Operational Hazard Warnings
- Commissioning with Control Signal Terminals (Factory Setting)
- Operational Data Indicator (Operational)
- Voltage, Acceleration Ramp 3s
- Brief Instructions: Steps to the Motor Start
- List of Fault Messages (F) and Warning Messages (AL)
- Error Messages via Operating Unit
- Control Unit
- LCD Display (Areas)
- Setting Parameters
- Parameter Menu (PAR)
- Default I/O
- Analog Inputs AI1 and AI2
- Example of Scaled Analog Input Signals
- Filter Time Constant
- Digital Inputs for Source and Sink Type
- Digital Inputs
- DI1 (FWD) + DI2 = REV
- Analog Output AO
- Digital Outputs
- Drives Control
- Acceleration and Deceleration Time
- S-Formed Curve for Acceleration and Deceleration Ramps
- Automatic Restart After Error Message (Two Start Attempts)
- Motor Parameters from Ratings Plate
- Motor
- Protective Functions
- Motor Cooling Power
- PID Controller
- Function Chart for OD (PID System Deviation)
- PID Controller, Actual Value Message FBV
- Fixed Frequencies FF1, FF2 and FF3 (= FF1 + FF2)
- Fixed Frequency Setpoint Value
- Determining the Program Number (P10.10)
- Example A, Program Cycle Executed Once (P10.9 = 1, P10.10 = 0)
- Example B, Program Cycle Executed Once (P10.9 = 1, P10.10 = 192)
- Example C, Program Cycle Executed Once in Steps (P10.9 = 2, P10.10 = 0)
- V/Hz-Characteristic Curve
- V/Hz-Characteristic Curve (P11.1)
- Speed Behavior without Slip Compensation
- Braking
- Regenerative Braking with External Braking Resistor
- Mechanical Brake
- Logic Linking of A and B
- Logic Function
- Second Parameter Set
- Roller Conveyor with Rotary Table
- Stop Function with Two Different Deceleration Times
- System Parameter
- Operational Data Indicator (MON)
- Status Displays Examples
- Setpoint Input (REF)
- General Information About Modbus
- Modbus Parameters
- Data Exchange Between Master and Slave
- Error Code Description
- Modbus Process Data
- Special Technical Data
- Device Series MMX12
- Device Series MMX32
- Device Series MMX34
- Device Series MMX35
- Dimensions and Frame Sizes
- Dimensions and Frame Sizes, FS4 and FS5 (FS = Frame Size)
- PC Interface Card
- Upload
- Mounting Frame for Fieldbus Connection
- Fitting and Connecting the Mounting Plate of the MMX-NET-XA
- MMX-NET-XB Interface Module
- the Fieldbus Interface Cards
- PROFIBUS DP Fieldbus Interface Card
- Cables, Fuses and Disconnect Devices
- List of Parameters
- System Parameters in the Quick Start
- Parameter Selection
- Digital Input
- Analog Output
- Digital Output
- Fixed Frequencies
- System Parameters
- Parameter Values Currently Being Measured
- Door Panel Keypad Adapter System—Mounting Instructions
- Door Keypad Mounting Instructions
- Door Keypad Mounting Instructions, continued
- Door Keypad Cut-out Dimensions
- Door Keypad Dimensions
M-Max series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Notes on the second MMX upgrade
- Writing conventions
- Abbreviations and Symbols
- System overview
- Checking the Delivery
- Rating data on the nameplate
- Key to part numbers
- General rated operational data
- Technical data
- Features
- Selection criteria
- Proper use
- Maintenance and inspection
- Introduction
- Electrical power network
- Idle power compensation devices
- Safety and switching
- Mains contactor
- Motor and Application
- Motor and circuit type
- Bypass operation
- Fixing
- EMC installation
- Electrical Installation
- Connection to power section
- Arrangement and connection of the power terminals
- Connection on control section
- Arrangement and connection of the control signal terminals
- Function of the control signal terminals
- Block diagram
- Insulation testing
- Operation
- Operational hazard warnings
- Commissioning with control signal terminals (factory setting)
- Brief Instructions
- Error and Warning Messages
- Parameters
- Display unit
- Setting parameters
- Parameter menu (PAR)
- Quickstart Wizard
- Parameter selection (P1)
- Analog input (P2)
- Digital input (P3)
- Analog output (P4)
- Digital output (P5)
- Drives control (P6)
- Motor (P7)
- Protective functions (P8)
- PID controller (P9)
- Fixed frequency setpoint value (P10)
- U/f-characteristic curve (P11)
- Braking (P12)
- Logic function (P13)
- Second parameter set (P14)
- System parameter
- Operational data indicator (MON)
- Setpoint input (REF)
- Serial interface (Modbus RTU)
- Modbus parameters
- Operating mode Modbus RTU
- Structure of the master request
- Data storage with Modbus
- Modbus Process Data
- Explanation of function code
- Appendix
- Device series MMX12
- Device series MMX32
- Device series MMX34
- Dimensions and frame size
- MMX-COM-PC
- MMX-NET-XA
- XMX-NET-CO-A
- XMX-NET-PD-A, XMX-NET-PS-A
- Cables and fuses
- Mains contactors
- Radio interference suppression filters
- Special technical data for MMX-LZ
- Dimensions and sizes of the MMX-LZ... interference suppression filters
- Brake resistors
- Brake resistors BR1...-T-PF and BR3
- Mains chokes
- Motor chokes
- Sinusoidal filters
- List of parameters
- All Parameters
- Index
M-Max series
Table of contents
- Table Of Contents
- Table Of Contents
- About this manual
- Figure 2: Control Signal Terminals
- Writing conversions
- Rated operational data on the nameplate
- Technical Data
- Table 2: General Rated Operational Data
- Table 3: Technical Data
- Control signal terminals
- Table 4: Cable Cross Section (Cu): 0.5 – 1.5 mm 2
- Block diagram
- Figure 5: MMX12 Block Diagram
- Figure 6: Block Diagram MMX32 and MMX34
- Checklist for commissioning
- Hazard warnings
- Introduction
- Fault log (FLT)
- Table 5: List of Fault Messages (F) and Warning Messages (AL)
- Control unit
- Display unit
- General information on menu navigation
- Setting parameters
- Parameter menu (PAR)
- Figure 13: Schematic Representation of Parameter Access
- Quick start wizard
- Example: Motor parameters (P7)
- List of parameters
- Table 10: Predefined Application Parameters From Parameter P1.2
- All Parameters
- February
M-Max series
Table of contents
manualsdatabase
Your AI-powered manual search engine