GE Multilin D60 Line Distance Protection System B-65APPENDIX B B.4 MEMORY MAPPINGBB08D IEC 61850 LPHD Location 0 to 65534 --- --- F204 “Location”B0B5 Include non-IEC 61850 Data 0 to 1 --- 1 F102 0 (Disabled)B0B6 IEC 61850 Server Data Scanning Function 0 to 1 --- 1 F102 0 (Disabled)B0B7 IEC 61850 LPHD Latitude -90 to 90 degree 0.001 F004 0B0B9 IEC 61850 LPHD DC PhyNam Longitude -180 to 180 degree 0.001 F004 0B9BB IEC 61850 LPHD DC PhyNam Altitude 0 to 10000 m 1 F003 0B0BD Reserved (3 items) 0 to 1 --- 1 F001 0IEC 61850 MMXU Deadbands (Read/Write Setting) (6 Modules)B0C0 IEC 61850 MMXU TotW Deadband 1 0.001 to 100 % 0.001 F003 10000B0C2 IEC 61850 MMXU TotVAr Deadband 1 0.001 to 100 % 0.001 F003 10000B0C4 IEC 61850 MMXU TotVA Deadband 1 0.001 to 100 % 0.001 F003 10000B0C6 IEC 61850 MMXU TotPF Deadband 1 0.001 to 100 % 0.001 F003 10000B0C8 IEC 61850 MMXU Hz Deadband 1 0.001 to 100 % 0.001 F003 10000B0CA IEC 61850 MMXU PPV.phsAB Deadband 1 0.001 to 100 % 0.001 F003 10000B0CC IEC 61850 MMXU PPV.phsBC Deadband 1 0.001 to 100 % 0.001 F003 10000B0CE IEC 61850 MMXU PPV.phsCA Deadband 1 0.001 to 100 % 0.001 F003 10000B0D0 IEC 61850 MMXU PhV.phsADeadband 1 0.001 to 100 % 0.001 F003 10000B0D2 IEC 61850 MMXU PhV.phsB Deadband 1 0.001 to 100 % 0.001 F003 10000B0D4 IEC 61850 MMXU PhV.phsC Deadband 1 0.001 to 100 % 0.001 F003 10000B0D6 IEC 61850 MMXU A.phsA Deadband 1 0.001 to 100 % 0.001 F003 10000B0D8 IEC 61850 MMXU A.phsB Deadband 1 0.001 to 100 % 0.001 F003 10000B0DA IEC 61850 MMXU A.phsC Deadband 1 0.001 to 100 % 0.001 F003 10000B0DC IEC 61850 MMXU A.neut Deadband 1 0.001 to 100 % 0.001 F003 10000B0DE IEC 61850 MMXU W.phsA Deadband 1 0.001 to 100 % 0.001 F003 10000B0E0 IEC 61850 MMXU W.phsB Deadband 1 0.001 to 100 % 0.001 F003 10000B0E2 IEC 61850 MMXU W.phsC Deadband 1 0.001 to 100 % 0.001 F003 10000B0E4 IEC 61850 MMXU VAr.phsA Deadband 1 0.001 to 100 % 0.001 F003 10000B0E6 IEC 61850 MMXU VAr.phsB Deadband 1 0.001 to 100 % 0.001 F003 10000B0E8 IEC 61850 MMXU VAr.phsC Deadband 1 0.001 to 100 % 0.001 F003 10000B0EA IEC 61850 MMXU VA.phsA Deadband 1 0.001 to 100 % 0.001 F003 10000B0EC IEC 61850 MMXU VA.phsB Deadband 1 0.001 to 100 % 0.001 F003 10000B0EE IEC 61850 MMXU VA.phsC Deadband 1 0.001 to 100 % 0.001 F003 10000B0F0 IEC 61850 MMXU PF.phsA Deadband 1 0.001 to 100 % 0.001 F003 10000B0F2 IEC 61850 MMXU PF.phsB Deadband 1 0.001 to 100 % 0.001 F003 10000B0F4 IEC 61850 MMXU PF.phsC Deadband 1 0.001 to 100 % 0.001 F003 10000B0F6 ...Repeated for Deadband 2B12C ...Repeated for Deadband 3B162 ...Repeated for Deadband 4B198 ...Repeated for Deadband 5B1CE ...Repeated for Deadband 6IEC 61850 Received Analogs (Read Only) (32 Modules)B210 IEC 61850 Received Analog 1 -1000000000000 to1000000000000--- 0.001 F060 0B212 ...Repeated for Received Analog 2B214 ...Repeated for Received Analog 3B216 ...Repeated for Received Analog 4B218 ...Repeated for Received Analog 5B21A ...Repeated for Received Analog 6B21C ...Repeated for Received Analog 7B21E ...Repeated for Received Analog 8B220 ...Repeated for Received Analog 9B222 ...Repeated for Received Analog 10B224 ...Repeated for Received Analog 11B226 ...Repeated for Received Analog 12Table B–10: MODBUS MEMORY MAP (Sheet 57 of 77)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT