B-62 G30 Generator Protection System GE MultilinB.4 MEMORY MAPPING APPENDIX BBC908 ...Repeated for Direct Input 31C90C ...Repeated for Direct Input 32Direct Input/Output Alarms (Read/Write Setting)CAD0 Direct Input/Output Channel 1 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)CAD1 Direct Input/Output Channel 1 CRC Alarm Message Count 100 to 10000 --- 1 F001 600CAD2 Direct Input/Output Channel 1 CRC Alarm Threshold 1 to 1000 --- 1 F001 10CAD3 Direct Input/Output Channel 1 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)CAD4 Reserved (4 items) 1 to 1000 --- 1 F001 10CAD8 Direct Input/Output Channel 2 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)CAD9 Direct Input/Output Channel 2 CRC Alarm Message Count 100 to 10000 --- 1 F001 600CADA Direct Input/Output Channel 2 CRC Alarm Threshold 1 to 1000 --- 1 F001 10CADB Direct Input/Output Channel 2 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)CADC Reserved (4 items) 1 to 1000 --- 1 F001 10CAE0 Direct Input/Output Ch 1 Unreturned Messages AlarmFunction0 to 1 --- 1 F102 0 (Disabled)CAE1 Direct Input/Output Ch 1 Unreturned Messages Alarm MsgCount100 to 10000 --- 1 F001 600CAE2 Direct Input/Output Ch 1 Unreturned Messages AlarmThreshold1 to 1000 --- 1 F001 10CAE3 Direct Input/Output Ch 1 Unreturned Messages AlarmEvents 0 to 1 --- 1 F102 0 (Disabled)CAE4 Reserved (4 items) 1 to 1000 --- 1 F001 10CAE8 Direct Input/Output Ch 2 Unreturned Messages AlarmFunction 0 to 1 --- 1 F102 0 (Disabled)CAE9 Direct Input/Output Ch 2 Unreturned Messages Alarm MsgCount100 to 10000 --- 1 F001 600CAEA Direct Input/Output Ch 2 Unreturned Messages AlarmThreshold1 to 1000 --- 1 F001 10CAEB Direct Input/Output Channel 2 Unreturned Messages AlarmEvents 0 to 1 --- 1 F102 0 (Disabled)CAEC Reserved (4 items) 1 to 1000 --- 1 F001 10Remote Devices (Read/Write Setting) (16 modules)CB00 Remote Device 1 GSSE/GOOSE Application ID (GOID) --- --- --- F209 “Remote Device1“CB21 Remote Device 1 GOOSE Ethernet APPID 0 to 16383 --- 1 F001 0CB22 Remote Device 1 GOOSE Dataset 0 to 16 --- 1 F184 0 (Fixed)CB23 Remote Device 1 in PMU Scheme 0 to 1 --- 1 F126 0 (No)CB24 Reserved 0 to 3 --- 1 F626 0 (None)CB25 ...Repeated for Device 2CB4A ...Repeated for Device 3CB6F ...Repeated for Device 4CB94 ...Repeated for Device 5CBB9 ...Repeated for Device 6CBDE ...Repeated for Device 7CC03 ...Repeated for Device 8CC28 ...Repeated for Device 9CC4D ...Repeated for Device 10CC72 ...Repeated for Device 11CC97 ...Repeated for Device 12CCBC ...Repeated for Device 13CCE1 ...Repeated for Device 14CD06 ...Repeated for Device 15CD2B ...Repeated for Device 16Remote Inputs (Read/Write Setting) (32 modules)CFA0 Remote Input 1 Device 1 to 32 --- 1 F001 1CFA1 Remote Input 1 Bit Pair 0 to 96 --- 1 F156 0 (None)CFA2 Remote Input 1 Default State 0 to 3 --- 1 F086 0 (Off)Table B–10: MODBUS MEMORY MAP (Sheet 54 of 60)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT