B-52 L30 Line Current Differential System GE MultilinB.4 MEMORY MAPPING APPENDIX BBC65C ...Repeated for Contact Output 46C668 ...Repeated for Contact Output 47C674 ...Repeated for Contact Output 48C680 ...Repeated for Contact Output 49C68C ...Repeated for Contact Output 50C698 ...Repeated for Contact Output 51C6A4 ...Repeated for Contact Output 52C6B0 ...Repeated for Contact Output 53C6BC ...Repeated for Contact Output 54C6C8 ...Repeated for Contact Output 55C6D4 ...Repeated for Contact Output 56C6E0 ...Repeated for Contact Output 57C6EC ...Repeated for Contact Output 58C6F8 ...Repeated for Contact Output 59C704 ...Repeated for Contact Output 60C710 ...Repeated for Contact Output 61C71C ...Repeated for Contact Output 62C728 ...Repeated for Contact Output 63C734 ...Repeated for Contact Output 64Reset (Read/Write Setting)C750 FlexLogic™ operand which initiates a reset 0 to 65535 --- 1 F300 0Control Pushbuttons (Read/Write Setting) (7 modules)C760 Control Pushbutton 1 Function 0 to 1 --- 1 F102 0 (Disabled)C761 Control Pushbutton 1 Events 0 to 1 --- 1 F102 0 (Disabled)C762 ...Repeated for Control Pushbutton 2C764 ...Repeated for Control Pushbutton 3C766 ...Repeated for Control Pushbutton 4C768 ...Repeated for Control Pushbutton 5C76A ...Repeated for Control Pushbutton 6C76C ...Repeated for Control Pushbutton 7Clear Records (Read/Write Setting)C770 Clear Fault Reports operand 0 to 65535 --- 1 F300 0C772 Clear Event Records operand 0 to 65535 --- 1 F300 0C773 Clear Oscillography operand 0 to 65535 --- 1 F300 0C774 Clear Data Logger operand 0 to 65535 --- 1 F300 0C775 Clear Breaker 1 Arcing Current operand 0 to 65535 --- 1 F300 0C776 Clear Breaker 2 Arcing Current operand 0 to 65535 --- 1 F300 0C777 Clear Breaker 3 Arcing Current operand 0 to 65535 --- 1 F300 0C778 Clear Breaker 4 Arcing Current operand 0 to 65535 --- 1 F300 0C77C Clear Channel Status operand 0 to 65535 --- 1 F300 0C77F Clear Unauthorized Access operand 0 to 65535 --- 1 F300 0C782 Reserved (13 items) --- --- --- F001 0Force Contact Inputs/Outputs (Read/Write Settings)C7A0 Force Contact Input x State (96 items) 0 to 2 --- 1 F144 0 (Disabled)C800 Force Contact Output x State (64 items) 0 to 3 --- 1 F131 0 (Disabled)Channel Tests (Read/Write)C840 Local Loopback Function 0 to 1 --- 1 F126 0 (No)C841 Local Loopback Channel 1 to 2 --- 1 F001 1C842 Remote Loopback Function 0 to 1 --- 1 F126 0 (No)C843 Remote Loopback Channel 1 to 2 --- 1 F001 1C844 Remote Diagnostics Transmit 0 to 2 --- 1 F223 0 (NO TEST)Direct Input/Output Settings (Read/Write Setting)C850 Direct Input Default States (8 items) 0 to 1 --- 1 F108 0 (Off)C858 Direct Input Default States (8 items) 0 to 1 --- 1 F108 0 (Off)Table B–9: MODBUS MEMORY MAP (Sheet 44 of 52)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT