B-18 L60 Line Phase Comparison Relay GE MultilinB.4 MEMORY MAPPING APPENDIX BB40A6 Main UDP Port Number for the TFTP Protocol 1 to 65535 --- 1 F001 6940A7 Data Transfer UDP Port Numbers for the TFTP Protocol(zero means “automatic”) (2 items)0 to 65535 --- 1 F001 040A9 DNP Unsolicited Responses Function 0 to 1 --- 1 F102 0 (Disabled)40AA DNP Unsolicited Responses Timeout 0 to 60 s 1 F001 540AB DNP unsolicited responses maximum retries 1 to 255 --- 1 F001 1040AC DNP unsolicited responses destination address 0 to 65519 --- 1 F001 140AD Ethernet operation mode 0 to 1 --- 1 F192 0 (Half-Duplex)40AE DNP current scale factor 0 to 8 --- 1 F194 2 (1)40AF DNP voltage scale factor 0 to 8 --- 1 F194 2 (1)40B0 DNP power scale factor 0 to 8 --- 1 F194 2 (1)40B1 DNP energy scale factor 0 to 8 --- 1 F194 2 (1)40B2 DNP power scale factor 0 to 8 --- 1 F194 2 (1)40B3 DNP other scale factor 0 to 8 --- 1 F194 2 (1)40B4 DNP current default deadband 0 to 65535 --- 1 F001 3000040B6 DNP voltage default deadband 0 to 65535 --- 1 F001 3000040B8 DNP power default deadband 0 to 65535 --- 1 F001 3000040BA DNP energy default deadband 0 to 65535 --- 1 F001 3000040BE DNP other default deadband 0 to 65535 --- 1 F001 3000040C0 DNP IIN time synchronization bit period 1 to 10080 min 1 F001 144040C1 DNP message fragment size 30 to 2048 --- 1 F001 24040C2 DNP client address 3 0 to 4294967295 --- 1 F003 040C4 DNP client address 4 0 to 4294967295 --- 1 F003 040C6 DNP client address 5 0 to 4294967295 --- 1 F003 040C8 DNP number of paired binary output control points 0 to 16 --- 1 F001 040C9 DNP TCP connection timeout 0 to 16 --- 1 F001 040CA Reserved (22 items) 0 to 1 --- 1 F001 040E0 TCP port number for the IEC 60870-5-104 protocol 1 to 65535 --- 1 F001 240440E1 IEC 60870-5-104 protocol function 0 to 1 --- 1 F102 0 (Disabled)40E2 IEC 60870-5-104 protocol common address of ASDU 0 to 65535 --- 1 F001 040E3 IEC 60870-5-104 protocol cyclic data transmit period 1 to 65535 s 1 F001 6040E4 IEC 60870-5-104 current default threshold 0 to 65535 --- 1 F001 3000040E6 IEC 60870-5-104 voltage default threshold 0 to 65535 --- 1 F001 3000040E8 IEC 60870-5-104 power default threshold 0 to 65535 --- 1 F001 3000040EA IEC 60870-5-104 energy default threshold 0 to 65535 --- 1 F001 3000040EC IEC 60870-5-104 power default threshold 0 to 65535 --- 1 F001 3000040EE IEC 60870-5-104 other default threshold 0 to 65535 --- 1 F001 3000040F0 IEC 60870-5-104 client address (5 items) 0 to 4294967295 --- 1 F003 040FD Reserved (60 items) 0 to 1 --- 1 F001 04140 DNP object 1 default variation 1 to 2 --- 1 F001 24141 DNP object 2 default variation 1 to 2 --- 1 F001 24142 DNP object 20 default variation 0 to 3 --- 1 F523 0 (1)4143 DNP object 21 default variation 0 to 3 --- 1 F524 0 (1)4144 DNP object 22 default variation 0 to 3 --- 1 F523 0 (1)4145 DNP object 23 default variation 0 to 3 --- 1 F523 0 (1)4146 DNP object 30 default variation 1 to 5 --- 1 F001 14147 DNP object 32 default variation 0 to 5 --- 1 F525 0 (1)Simple Network Time Protocol (Read/Write Setting)4168 Simple Network Time Protocol (SNTP) function 0 to 1 --- 1 F102 0 (Disabled)4169 Simple Network Time Protocol (SNTP) server IP address 0 to 4294967295 --- 1 F003 0416B Simple Network Time Protocol (SNTP) UDP port number 1 to 65535 --- 1 F001 123Data Logger Commands (Read/Write Command)4170 Data Logger Clear 0 to 1 --- 1 F126 0 (No)Table B–9: MODBUS MEMORY MAP (Sheet 11 of 51)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT