5 - 42 Genie S-60 & Genie S-65 Part No. 48412Service Manual - Second EditionSection 5 - Troubleshooting Flow ChartsChart 18TurntableRotate LeftFunctionInoperativeBe sure all otherfunctions operatenormally.With key switch inground position andboth Emergency Stopbuttons pulled out to theON position, move thefunction enable switch toeither side and hold theturntable rotate toggleswitch (TS18) on groundpanel in the left directionand check voltage onwht/red wire on turntablerotate left/rightproportional valve coil(item R).0V20V or moreMove the functionenable switch to eitherside and hold theturntable rotate toggleswitch (TS18) on groundpanel in the left directionand check voltage atTB6.4 to 6VRepair open in wht/redwire circuit from TB6 toturntable rotate left/rightproportional valve coil(item R) OR repair openin brown ground wirecircuit to valve coil.0VWith keyswitch inplatform position andboth Emergency Stopbuttons pulled out to theon position, activatefootswitch and turntablerotate left/rightproportional controller(BP1) on platformcontrol panel in the leftdirection and checkvoltage at TP6.Continued on the nextpage.Repair open in wht/redwire from TP6 to TB6.0VActivate footswitch andcheck voltage at "+"terminal on BP1.12V or more0V Repair open in powersupply circuit from TP24to BP1 OR repair openin brown ground wirecircuit from ground toBP1.Re-adjust controller (seeRepair Section) ORreplace controller BP1OR consult GenieIndustries ServiceDepartment.4 to 6V800-610-4101ActionRental.com