Part No. 48412 Genie S-60 & Genie S-65 4 - 3Service Manual - Second Edition Section 4 - Scheduled Maintenance ProceduresTABLE A PROCEDURESA-4Check the Engine Oil LevelMaintaining the proper engine oil level is essentialto good engine performance and service life.Operating the machine with an improper oil levelcan damage engine components.Check the oil level with theengine off.1 Check the oil dipstick. Add oil as needed.Result: The oil level should be in the "safe"zone.Ford LRG-423 Engine 5 quartsOil capacity (including filter) 4.7 litersFord LRG-423 EngineOil viscosity requirementsbelow 60°F / 15.5°C 5W-30-10° to 90°F / -23° to 32°C 10W-30above -10°F / -23°C 10W-40 or 10W-50above 25°F / -4°C 20W-40 or 20W-50Use oils meeting API classification SF (labeled SF/CCor SF/CD) as they offer improved wear protection.Deutz Engine F4L 1011F 11 quartsOil capacity (including filter) 10.5 litersDeutz Engine F4L 1011F Oil viscosity requirementsbelow 60°F / 15.5°C (synthetic) 5W-30-10°F to 90°F / -23°C to 32°C 10W-40above -4°F / -34°C 15W-40Engine oil should have properties of API classificationCC/SE, CD/SE, SF/CC or SF/CD grades.A-5Check the Engine Coolant Level- Gasoline/LPG ModelsMaintaining the engine coolant at the proper levelis essential to engine service life. Improper coolantlevel will affect the engine's cooling capability anddamage engine components. Daily checks willallow the inspector to identify changes in coolantlevel that might indicate cooling system problems.1 Check the fluid level in the coolant recoverytank. Add fluid as needed.Result: The fluid level should be in theNORMAL range.Fluids in the radiator are underpressure and extremely hot. Usecaution when removing cap andadding fluids.A-6Check for Fuel LeaksFailure to detect and correct fuel leaks will result inan unsafe condition. An explosion or fuel fire maycause death or serious injury.Engine fuels are combustible.Inspect the machine in an open,well-ventilated area away fromheaters, sparks, flames andlighted tobacco. Always have anapproved fire extinguisher withineasy reach.1 Open the shutoff valve on the liquid petroleumgas (LPG) tank by turning it counterclockwise.2 Perform a visual inspection around the followingareas. (An LPG detector may be necessary tolocate LPG leaks.)800-610-4101ActionRental.com