Service and Repair Manual October 2016Fault Code Display - Deutz and Perkins Models96 S-80 • S-85 • S-80X Part No. 1269074Faul t Code Dis play - Flashi ng and Solid LED's - D eutz D 2.9 L4 and Per ki ns 404F- 22 ModelsFlashing and Solid LED's - Deutz D 2.9 L4 and Perkins 404F-22 Models1 Left green LED:Flashing, engine fault detected. Contact service.Solid, fault acknowledged. Contact service.2 Left amber LED: (Perkins models)Solid,a) Regeneration is inhibited. No service required.b) High exhaust temperature during regeneration mode. No service required.3 Left red LED:Flashing, engine fault detected. Contact service.Flashing with right flashing amber LED, engine soot level over 140%. Engine shut down. Contact service.4 Right green LED:Flashing, engine fault detected. Contact service.Solid, fault acknowledged. Contact service.5 Right amber LED: (Perkins models)Solid with left amber LED on solid, regeneration has been inhibited and engine soot level is between 80 - 100%.Regeneration is required.Flashing with left amber LED on solid, regeneration has been inhibited and soot level is between 100 - 140%. Enginerpm is de-rated. Regeneration is required.Flashing with left and right red LED's flashing, engine soot level over 140%. Engine shut down. Contact service.6 Right red LED:Flashing, engine fault detected. Contact service.Flashing with right flashing amber LED, engine soot level over 140%. Engine shut down. Contact service.